Génération du PDF…

Merci de patienter quelques secondes

Fiche technique — fb4f401f943f — 33548

33548

fb4f401f943f

Fiche technique · 25 mai 2026

33548

33548

fb4f401f943f

En stock

CIRCUIT BREAKER COMPACT NS630BL MICROLOG

Catégorie : Disjoncteurs forte puissance (boitier moulé et ouvert)

Caractéristiques complémentaires

circuit breaker Compact NS630bL Micrologic 5.0
- 630 A 3 poles 3t
Suitability for isolation Yes conforming to IEC 60947 2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947 2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947 2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947 2
Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Breaking capacity 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947 2
100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947 2
130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947 2
150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947 2
150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947 2
[Ics] rated service breaking capacity Ics 100 kA 500/525 V AC 50/60 Hz conforming to IEC 60947 2
Ics 130 kA 440 V AC 50/60 Hz conforming to IEC 60947 2
Ics 150 kA 220/240 V AC 50/60 Hz conforming to IEC 60947 2
Ics 150 kA 380/415 V AC 50/60 Hz conforming to IEC 60947 2
Ics 25 kA 660/690 V AC 50/60 Hz conforming to IEC 60947 2
Electrical durability 3000 cycles IEC 60947 2 690 V In/2 AC 50/60 Hz
2000 cycles IEC 60947 2 690 V In AC 50/60 Hz
3000 cycles IEC 60947 2 440 V In AC 50/60 Hz
4000 cycles IEC 60947 2 440 V In/2 AC 50/60 Hz
Short time short circuit protection
Instantaneous short circuit protection
Long time pick up adjstment type Ir Adjustable
Long time pick up adjustment range 0.4...1 x In
[Tr] long time delay adjustment 0.7...16.6 s 7.2 x Ir
Short time pick-up adjustment type Isd Adjustable 9 settings
[Isd] short time pick-up adjustment 1.5...10 A
Short time delay adjustment type Adjustable 5 settings
[Tsd] short time delay adjustment 0.02...0.5 s
Instantaneous pick up adjustment type Adjustable
Instantaneous pick up adjustment 2...15 x In
IEC 60947 2
Ambient air temperature for operation 25...70 °C
Ambient air temperature for storage 50...85 °C