CIRCUIT BREAKER COMPACT NS630BN MICROLOG

Catégorie : Disjoncteurs forte puissance (boitier moulé et ouvert)

Caractéristiques complémentaires

circuit breaker Compact NS630bN Micrologic 5.0
- 630 A 4 poles 4t
Suitability for isolation Yes conforming to IEC 60947 2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947 2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947 2
Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947 2
Breaking capacity 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947 2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947 2
50 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947 2
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947 2
40 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947 2
40 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947 2
[Ics] rated service breaking capacity Ics 30 kA 660/690 V AC 50/60 Hz conforming to IEC 60947 2
Ics 40 kA 500/525 V AC 50/60 Hz conforming to IEC 60947 2
Ics 50 kA 220/240 V AC 50/60 Hz conforming to IEC 60947 2
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947 2
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947 2
Electrical durability 5000 cycles IEC 60947 2 440 V In AC 50/60 Hz
2000 cycles IEC 60947 2 690 V In AC 50/60 Hz
4000 cycles IEC 60947 2 690 V In/2 AC 50/60 Hz
6000 cycles IEC 60947 2 440 V In/2 AC 50/60 Hz
[Icw] rated short time withstand current 19.2 kA
Protection type Short time short circuit protection
Instantaneous short circuit protection
Long time pick up adjstment type Ir Adjustable
Long time pick up adjustment range 0.4...1 x In
[Tr] long time delay adjustment 0.7...16.6 s 7.2 x Ir
Short time pick-up adjustment type Isd Adjustable 9 settings
[Isd] short time pick-up adjustment 1.5...10 A
Short time delay adjustment type Adjustable 5 settings
[Tsd] short time delay adjustment 0.02...0.5 s
Instantaneous pick up adjustment type Adjustable
Instantaneous pick up adjustment 2...15 x In
Standards IEC 60947 2
Ambient air temperature for operation 25...70 °C