substation - S84 - Sepam series 80Main

Catégorie : Schneider

Caractéristiques complémentaires

substation S84 - Sepam series 80
Control and monitoring type Circuit breaker/contactor control ANSI code 94/69 ( option )
Latching/Acknowledgement ANSI code 86
Logic discrimination ANSI code 68 ( option )
Annunciation ANSI code 30
Metering type Measured residual current I0, calculated I'0
Calculated active and reactive energy (+/ W.h, +/- VAR.h)
Active and reactive energy by pulse counting (+/ W.h, +/- VAR.h) ( option )
Difference in amplitude, frequency and phase of voltages with synchro check ( option )
Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Apparent phase to-phase impedances Z21, Z32, Z13
Switchgear diagnosis type CT/VT supervision ANSI code 60FL
Trip circuit supervision ANSI code 74 ( option )
Protection type Directional active underpower  ANSI code   37P
Rate of change of frequency  ANSI code   81R
Directional earth fault ANSI code 67N/67NC
Directional phase overcurrent ANSI code 67
Synchro check ( option ) ANSI code: 25
Overvoltage (L L or L-N) ANSI code: 59
Thermal overload for cables ANSI code 49RMS
Earth fault/sensitive earth fault ANSI code 50N/51N
Earth fault/sensitive earth fault ANSI code 50G/51G
Negative sequence/unbalance ANSI code 46
Remanent undervoltage ANSI code 27R
Overfrequency ANSI code 81H
Underfrequency ANSI code 81L
Negative sequence overvoltage ANSI code 47
Directional active overpower ANSI code 32P
Positive sequence undercurrent ANSI code 27D
Undervoltage (L L or L-N) ANSI code: 27
Breaker failure ANSI code 50BF
Neutral voltage displacement ANSI code 59N
Phase overcurrent ANSI code 50/51
Recloser (4 cycles) ( option ) ANSI code 79
Communication port protocol Measurement readout ( option ) Modbus
Remote control orders ( option ) Modbus
Remote indication and time tagging of events ( option ) Modbus
Remote protection setting ( option ) Modbus
Transfer of disturbance recording data ( option ) Modbus
IEC 60870 5-103
Mimic based

Description