Fiche technique · 9 juin 2026
| iC60H | miniature circuit breaker - 4P - 40A - C |
|---|---|
| Product or component type Miniature circuit | breaker |
| Trip unit technology Thermal | magnetic |
| Breaking capacity 42 kA Icu conforming to IEC 60947 | 2 - 12...133 V AC 50/60 Hz |
| 42 kA Icu conforming to EN 60947 | 2 - 12...133 V AC 50/60 Hz |
| 15 kA Icu conforming to EN 60947 | 2 - 180...250 V DC |
| 15 kA Icu conforming to IEC 60947 | 2 - 180...250 V DC |
| 10 kA Icu conforming to IEC 60947 | 2 - 440 V AC 50/60 Hz |
| 10 kA Icu conforming to EN 60947 | 2 - 440 V AC 50/60 Hz |
| 10000 A Icn conforming to EN 60898 | 1 - 400 V AC 50/60 Hz |
| 10000 A Icn conforming to IEC 60898 | 1 - 400 V AC 50/60 Hz |
| 15 kA Icu conforming to EN 60947 | 2 - 380...415 V AC 50/60 Hz |
| 15 kA Icu conforming to IEC 60947 | 2 - 380...415 V AC 50/60 Hz |
| 30 kA Icu conforming to EN 60947 | 2 - 220...240 V AC 50/60 Hz |
| 30 kA Icu conforming to IEC 60947 | 2 - 220...240 V AC 50/60 Hz |
| Utilisation category Category A conforming to EN 60947 | 2 |
| Category A conforming to IEC 60947 | 2 |
| Suitability for isolation Yes conforming to EN 60947 | 2 |
| Yes conforming to IEC 60947 | 2 |
| Yes conforming to EN 60898 | 1 |
| Yes conforming to IEC 60898 | 1 |
| Standards IEC 60898 | 1 |
| EN 60947 | 2 |
| IEC 60947 | 2 |
| Disclaimer | This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications |
| EN 60898 | 1 |
| Magnetic tripping limit 8 x In +/ | 20 % |
| [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898 | 1 - 400 V AC 50/60 Hz |
| 7500 A 75 % x Icu conforming to IEC 60898 | 1 - 400 V AC 50/60 Hz |
| 21 kA 50 % x Icu conforming to IEC 60947 | 2 - 12...133 V AC 50/60 Hz |
| 21 kA 50 % x Icu conforming to EN 60947 | 2 - 12...133 V AC 50/60 Hz |
| 15 kA 100 % x Icu conforming to IEC 60947 | 2 - 180...250 V DC |
| 15 kA 100 % x Icu conforming to EN 60947 | 2 - 180...250 V DC |
| 5 kA 50 % x Icu conforming to IEC 60947 | 2 - 440 V AC 50/60 Hz |
| 15 kA 50 % x Icu conforming to EN 60947 | 2 - 220...240 V AC 50/60 Hz |
| 7.5 kA 50 % x Icu conforming to EN 60947 | 2 - 380...415 V AC 50/60 Hz |
| 5 kA 50 % x Icu conforming to EN 60947 | 2 - 440 V AC 50/60 Hz |
| 15 kA 50 % x Icu conforming to IEC 60947 | 2 - 220...240 V AC 50/60 Hz |
| 7.5 kA 50 % x Icu conforming to IEC 60947 | 2 - 380...415 V AC 50/60 Hz |
| Limitation class 3 conforming to EN 60898 | 1 |
| 3 conforming to IEC 60898 | 1 |
| [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947 | 2 |
| 500 V AC 50/60 Hz conforming to EN 60947 | 2 |
| [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947 | 2 |
| 6 kV conforming to IEC 60947 | 2 |
| Connections | terminals Single terminal, top or bottom rigid wire(s) 1...35 mm² max |
| Earth | leakage protection Separate block |
| Pollution degree 3 conforming to EN 60947 | 2 |
| 3 conforming to IEC 60947 | 2 |
| Tropicalisation 2 conforming to IEC 60068 | 1 |
| Ambient air temperature for operation | 35...70 °C |
| Ambient air temperature for storage | 40...85 °C |
| RoHS (date code | YYWW) Compliant - since 1001 - Schneider Electric declaration of conformity |
Le mécanisme de fermeture rapide indépendant améliore la longévité du dispositif. Sa classe de limitation 3 optimise la protection des circuits en aval tout en réduisant les coûts associés.
Le système Visisafe ajoute une couche de protection supplémentaire grâce à sa bande verte de sécurité. Cette indication visuelle confirme l'ouverture physique des contacts. Les techniciens peuvent ainsi intervenir sur les circuits en toute sérénité.
Dans le secteur commercial, il sécurise les circuits d'éclairage, la climatisation et les équipements sensibles des magasins. Pour l'industrie, sa robustesse permet de protéger efficacement les machines-outils et les lignes de production.
Clause de non-responsabilité : Cette fiche est fournie à titre informatif. Senia Electrique ne saurait être tenu responsable de l'utilisation de ces informations sans validation technique préalable. Document généré le 9 juin 2026. Source : https://seniadz.net/index.php/produit/a9f84440/