Fiche technique · 21 mai 2026
| iC60H | miniature circuit breaker - 4P - 63A - C |
|---|---|
| Product or component type Miniature circuit | breaker |
| Trip unit technology Thermal | magnetic |
| Breaking capacity 42 kA Icu conforming to IEC 60947 | 2 - 12...133 V AC 50/60 Hz |
| 42 kA Icu conforming to EN 60947 | 2 - 12...133 V AC 50/60 Hz |
| 15 kA Icu conforming to EN 60947 | 2 - 180...250 V DC |
| 15 kA Icu conforming to IEC 60947 | 2 - 180...250 V DC |
| 10 kA Icu conforming to IEC 60947 | 2 - 440 V AC 50/60 Hz |
| 10 kA Icu conforming to EN 60947 | 2 - 440 V AC 50/60 Hz |
| 10000 A Icn conforming to EN 60898 | 1 - 400 V AC 50/60 Hz |
| 10000 A Icn conforming to IEC 60898 | 1 - 400 V AC 50/60 Hz |
| 15 kA Icu conforming to EN 60947 | 2 - 380...415 V AC 50/60 Hz |
| 15 kA Icu conforming to IEC 60947 | 2 - 380...415 V AC 50/60 Hz |
| 30 kA Icu conforming to EN 60947 | 2 - 220...240 V AC 50/60 Hz |
| 30 kA Icu conforming to IEC 60947 | 2 - 220...240 V AC 50/60 Hz |
| Utilisation category Category A conforming to EN 60947 | 2 |
| Category A conforming to IEC 60947 | 2 |
| Suitability for isolation Yes conforming to EN 60947 | 2 |
| Yes conforming to IEC 60947 | 2 |
| Yes conforming to EN 60898 | 1 |
| Yes conforming to IEC 60898 | 1 |
| Standards EN 60898 | 1 |
| EN 60947 | 2 |
| IEC 60898 | 1 |
| Disclaimer | This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications |
| IEC 60947 | 2 |
| Magnetic tripping limit 8 x In +/ | 20 % |
| [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898 | 1 - 400 V AC 50/60 Hz |
| 7500 A 75 % x Icu conforming to IEC 60898 | 1 - 400 V AC 50/60 Hz |
| 21 kA 50 % x Icu conforming to IEC 60947 | 2 - 12...133 V AC 50/60 Hz |
| 21 kA 50 % x Icu conforming to EN 60947 | 2 - 12...133 V AC 50/60 Hz |
| 15 kA 100 % x Icu conforming to IEC 60947 | 2 - 180...250 V DC |
| 15 kA 100 % x Icu conforming to EN 60947 | 2 - 180...250 V DC |
| 5 kA 50 % x Icu conforming to IEC 60947 | 2 - 440 V AC 50/60 Hz |
| 15 kA 50 % x Icu conforming to EN 60947 | 2 - 220...240 V AC 50/60 Hz |
| 7.5 kA 50 % x Icu conforming to EN 60947 | 2 - 380...415 V AC 50/60 Hz |
| 5 kA 50 % x Icu conforming to EN 60947 | 2 - 440 V AC 50/60 Hz |
| 15 kA 50 % x Icu conforming to IEC 60947 | 2 - 220...240 V AC 50/60 Hz |
| 7.5 kA 50 % x Icu conforming to IEC 60947 | 2 - 380...415 V AC 50/60 Hz |
| [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947 | 2 |
| 500 V AC 50/60 Hz conforming to EN 60947 | 2 |
| [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947 | 2 |
| 6 kV conforming to IEC 60947 | 2 |
| Connections | terminals Single terminal, top or bottom rigid wire(s) 1...35 mm² max |
| Earth | leakage protection Separate block |
| Pollution degree 3 conforming to EN 60947 | 2 |
| 3 conforming to IEC 60947 | 2 |
| Tropicalisation 2 conforming to IEC 60068 | 1 |
| Ambient air temperature for operation | 35...70 °C |
| Ambient air temperature for storage | 40...85 °C |
| RoHS (date code | YYWW) Compliant - since 1001 - Schneider Electric declaration of conformity |
La conformité aux standards IEC 60947-2 assure un Ics (pouvoir de coupure de service) de 7500A, soit 75% de l'Icu. Cette caractéristique garantit une protection optimale contre les courts-circuits dans les installations tertiaires et industrielles.
La certification IP20 valide la protection contre les contacts directs, tandis que le marquage CE confirme le respect des directives européennes en vigueur. Le produit bénéficie également d'une certification VDE, attestant sa sécurité électrique selon les normes allemandes.
Les performances environnementales exceptionnelles de ce modèle sont reconnues par des écolabels stricts, assurant des composants recyclables et une empreinte carbone maîtrisée.