variable speed drive ATV32 - 3 kw - 400 V - 3 phase - with heat sink

Catégorie : Schneider

Caractéristiques complémentaires

variable speed drive ATV32 3 kw - 400 V - 3 phase
[Us] rated supply voltage 380...500 V 15...10 %
Supply frequency 50...60 Hz 5...5 %
Speed range 1...100 asynchronous motor in open loop mode
Speed accuracy +/ 10 % of nominal slip 0.2 Tn to Tn
Torque accuracy +/ 15 %
Flux vector control without sensor Energy Saving, NoLoad law
Voltage/frequency ratio Energy Saving, quadratic U/f
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/ 5 % <= 10
mA overload and short circuit protection
Bipolar differential voltage AI2 +/ 10 V DC 30000 Ohm 10 bits
Current AI3 0...20 mA (or 4 20 mA, x-20 mA, 20-x mA or other patterns by
Response time 8 ms +/ 0.7 ms LI1...LI6 logic
Accuracy +/ 0.2 % AI1, AI2, AI3 for a temperature of -10...60 °C
+/ 0.5 % AI1, AI2, AI3 for a temperature of 25 °C
+/ 1 % AO1 for a temperature of 25 °C
+/ 2 % AO1 for a temperature of -10...60 °C
Linearity error +/ 0.2...0.5 % of maximum value AI1, AI2, AI3
+/ 0.3 % AO1
Analogue output type Software configurable current AO1 0...20 mA 800 Ohm 10 bits
Software configurable voltage AO1 0...10 V 470 Ohm 10 bits
Switch configurable PTC probe LI6 24...30 V DC
Short circuit between motor phases drive
Physical interface 2 wire RS 485 Modbus
Electromagnetic compatibility 1.2/50 µs 8/20 µs surge immunity test level 3 IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 IEC 61000 4-4
Electrostatic discharge immunity test level 3 IEC 61000 4-2
Radiated radio frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Conducted radio frequency immunity test level 3 IEC 61000-4-6
Voltage dips and interruptions immunity test IEC 61000 4-11
EN 61800 3 environments 1 category C2
EN 61800 3 environments 2 category C2
EN/IEC 61800 3
EN/IEC 61800 5-1
C Tick
pollution degree 2 EN/IEC 61800 5-1
IP degree of protection IP20 EN/IEC 61800 5-1
vibration resistance 1 gn 13...200 Hz EN/IEC 60068 2-6
1.5 mm peak to peak 3...13 Hz EN/IEC 60068 2-6
shock resistance 15 gn 11 ms EN/IEC 60068 2-27
relative humidity 5...95 % without condensation IEC 60068 2-3
5...95 % without dripping water IEC 60068 2-3
ambient air temperature for operation 10...50 °C without derating
ambient air temperature for storage 25...70 °C
operating position Vertical +/ 10 degree
RoHS (date code YYWW) Compliant - since 1007 - Schneider Electric declaration of conformity
(2) Optional GV2 circuit breaker
Option Protection Device, GV2 circuit-breaker
The drive is prepared to be equipped with an optional GV2 circuit breaker.
The GV2 circuit breaker is directly mounted on the drive. Mechanical and electrical link are made using the optional adapter. The
NOTE The product overall dimension, including GV2 adapter and EMC plate mounted, becomes 424 mm (16.7 in.)
(1) Ground screw (HS type 2 5x12)
Single or Three phase Power Supply - Diagram with Line Contactor
Connection diagrams conforming to standards EN 954 1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in
accordance with standard IEC/EN 60204 1.
Single or Three phase Power Supply - Diagram with Switch Disconnect
Connection diagrams conforming to standards EN 954 1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in
accordance with standard IEC/EN 60204 1.
Connection diagrams conforming to standards EN 954 1 category 3 and IEC/EN 61508 capacity SIL2, stopping category 0 in
accordance with standard IEC/EN 60204 1.
category 0 of standard IEC/EN 60204 1.
The STO safety function integrated into the product can be used to implement an "EMERGENCY STOP" (IEC 60204 1) for category 0
Connection diagrams conforming to standards EN 954 1 category 2 and IEC/EN 61508 capacity SIL1, stopping category 0 in
accordance with standard IEC/EN 60204 1.
category 0 of standard IEC/EN 60204 1.
The STO safety function integrated into the product can be used to implement an "EMERGENCY STOP" (IEC 60204 1) for category 0
Switch SW1 set to
Switch SW1 set to
Switch SW1 set to
Switch SW1 set to

Description