THERMAL OVERLOAD RELAY EasyPact TVS

Catégorie : Contacteurs, sectionneurs, relais multifonctions

Caractéristiques complémentaires

16...24 A class 10A
one at 0 conforming to IEC 60947 4-1
Overload tripping class Class 10A conforming to IEC 60947 4-1
Tripping threshold 1.14 +/ 0.06 Ir conforming to IEC 60947-4-1
Mechanical robustness Shocks 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations 3 Gn conforming to IEC 60068-2-6
[Ith] conventional free air thermal current Control circuit 5 A
Associated fuse rating Control circuit 5 A (gG)
Power circuit 50 A (gG)
Power circuit 25 A (aM)
[Ui] rated insulation voltage 690 V conforming to IEC 60947 4-1
Control type Stop red push-button
Reset green push-button
Temperature compensation 20...60 °C
Connections terminals Screw clamp terminals (control circuit): 2 flexible cable(s) without cable end of 1...2.5
Screw clamp terminals (control circuit) 2 flexible cable(s) without cable end of 1...2.5
Screw clamp terminals (control circuit) 2 flexible cable(s) with cable end of 1...2.5
Screw clamp terminals (control circuit) 2 solid cable(s) without cable end of 1...2.5
Screw clamp terminals (power circuit) 1 flexible cable(s) without cable end of 2.5...10
Screw clamp terminals (power circuit) 1 flexible cable(s) with cable end of 1.5...6
Screw clamp terminals (power circuit) 1 solid cable(s) without cable end of 2.5...10
Tightening torque Control circuit (screw clamp terminals) 1.7 N.m
Control circuit (screw clamp terminals) 1.7 N.m
Power circuit (screw clamp terminals) 2.5 N.m
standards IEC 60947 4-1
IEC 60947 5-1
ambient air temperature for operation 20...70 °C with derating
-20...60 °C without derating conforming to IEC 60947 4-1
ambient air temperature for storage 60...80 °C
fire resistance 850 °C conforming to IEC 60068 2-1
dielectric strength 6 kV at 50 Hz conforming to IEC 60255 5
electromagnetic compatibility Surge withstand 6 kV conforming to IEC 60801-5
RoHS (date code YYWW) Compliant - since 1110 - Schneider Electric declaration of conformity

Description

Clause de non-responsabilité : Cette fiche est fournie à titre informatif. Senia Electrique ne saurait être tenu responsable de l'utilisation de ces informations sans validation technique préalable. Document généré le 31 mai 2026. Source : https://seniadz.net/index.php/produit/lre22/