En stock

TEMPO TRVAIL 20 30V DC 20 264V AC

Catégorie : Contrôle, Relais et Signalisation

Caractéristiques complémentaires

universal plug in timing relay - on-delay - 0.1 s..60
mn 24..240 V AC - 2 OC
Electrical connection Plug in sub-base 8 pin(s)
Housing material Self extinguishing
Repeat accuracy +/ 0.5 % conforming to IEC 61812-1
Temperature drift +/ 0.05 %/°C
Voltage drift +/ 0.2 %/V
Setting accuracy of time delay +/ 10 % of full scale at 25 °C conforming to IEC 61812-1
Reset time 100 ms on de energisation
Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
On load factor 100 %
[Uimp] rated impulse withstand voltage 5 kV for 1.2...50 µs conforming to IEC 60664 1
5 kV for 1.2...50 µs conforming to IEC 61812 1
Creepage distance 4 kV/3 conforming to IEC 60664 1
Surge withstand 1 kV (differential mode) conforming to IEC 61000 4-5 level 3
2 kV (common mode) conforming to IEC 61000 4-5 level 3
Local signalling LED indicator green flashing timing in progress
LED indicator green on steady relay energised, no timing in progress
LED indicator green pulsing relay energised, no timing in progress
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812 1
EN 50082 1/2
IEC 60669 2-3
EN 50081 1/2
IEC 61812 1
Ambient air temperature for operation 20...60 °C
Ambient air temperature for storage 30...60 °C
Vibration resistance 0.35 mm (f = 10...55 Hz) conforming to IEC 60068 2-6
Relative humidity 93 % without condensation conforming to IEC 60068 2-3
Resistance to electrostatic discharge 6 kV (in contact) conforming to IEC 61000 4-2 level 3
8 kV (in air) conforming to IEC 61000 4-2 level 3
10 V/m, 80 MHz to 1 GHz conforming to IEC 61000 4-3 level 3
Resistance to fast transients 1 kV, capacitive connecting clip conforming to IEC 61000 4-4 level 3
2 kV, direct conforming to IEC 61000 4-4 level 3
Immunity to radioelectric fields 10 V (0.15...80 MHz) conforming to ENV 50141 (IEC 61000 4-6)
Immunity to voltage dips 30 % / 10 ms conforming to IEC 61000 4-11
60 % / 100 ms conforming to IEC 61000 4-11
95 % / 5 s conforming to IEC 61000 4-11
Function A Power on Delay Relay
Function 1 Output
Function 2 Outputs
Relay de energised
Ta Adjustable On delay
Tr Adjustable Off delay

Description

Clause de non-responsabilité : Cette fiche est fournie à titre informatif. Senia Electrique ne saurait être tenu responsable de l'utilisation de ces informations sans validation technique préalable. Document généré le 7 juin 2026. Source : https://seniadz.net/index.php/produit/re88867215/