| industrial timing relay | 3..300 s - type C - 110..240 V |
|---|---|
| AC | 1 C/O |
| Connections | terminals Screw terminals 2 x 1.5 mm² , flexible cable with cable end |
| Setting accuracy of time delay +/ | 20 % of full scale |
| [Ie] rated operational current <= 2 A at 24 V, DC | 13 for 70 °C conforming to IEC 60947-5-1/1991 |
| <= 2 A at 24 V, DC | 13 for 70 °C conforming to VDE 0660 |
| <= 3 A at 24 V, AC | 15 for 70 °C conforming to IEC 60947-5-1/1991 |
| <= 3 A at 24 V, AC | 15 for 70 °C conforming to VDE 0660 |
| <= 0.1 A at 250 V, DC | 13 for 70 °C conforming to IEC 60947-5-1/1991 |
| <= 0.1 A at 250 V, DC | 13 for 70 °C conforming to VDE 0660 |
| <= 0.2 A at 115 V, DC | 13 for 70 °C conforming to IEC 60947-5-1/1991 |
| <= 0.2 A at 115 V, DC | 13 for 70 °C conforming to VDE 0660 |
| Input compatibility 2 | wire sensors DC with leakage current < 1 mA, cable length: <= 50 m (Y1) Marking CE Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage 250 V conforming to IEC 300 V conforming to CSA Supply disconnection value > 0.1 Uc |
| Surge withstand 2 kV conforming to IEC 61000 | 4-5 level 3 |
| Terminal description (15 | 16-18)OC_ON |
| (A1 | A2)CO |
| standards EN/IEC 61812 | 1 |
| ambient air temperature for storage | 40...85 °C |
| ambient air temperature for operation | 20...60 °C |
| relative humidity 15...85 % 3K3 conforming to IEC 60721 | 3-3 |
| vibration resistance 0.35 mm 10...55 Hz conforming to IEC 60068 | 2-6 |
| pollution degree 3 conforming to IEC 60664 | 1 |
| non | dissipating shock wave 4.8 kV |
| resistance to electrostatic discharge 6 kV in contact conforming to IEC 61000 | 4-2 level 3 |
| 8 kV in air conforming to IEC 61000 | 4-2 level 3 |
| resistance to electromagnetic fields 10 V/m conforming to IEC 61000 | 4-3 level 3 |
| resistance to fast transients 2 kV conforming to IEC 61000 | 4-4 level 3 |
| disturbance radiated/conducted CISPR 11 group 1 | class A |
| CISPR 22 | class A |
| The external control contact C may be an electronic control device, for example a true | wire sensor. In this case A1-A2= 24 Vdc and the |
| control device can only control | up to a maximum of 4 relays. |
| Connection of a 2 | Wire Sensor |
| Example | An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and |
| necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3 | k = 0.6 The electrical |
| durability therefore becomes | 1.5 10 operating cycles x 0.6 = 900 000 operating cycles. |
| Function C | Off-Delay Relay with Control Signal |
| After power | up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end |
| Function | 1 Output |
| Function | 2 Outputs |
| Relay de | energised |
| Ta | Adjustable On-delay |
| Tr | Adjustable Off-delay |