Retrouvez notre Stang au NAPEC 2025 – Oran

napec oran 2025

Nos marques

Tous les produits Schneider

Produits récemment consultés

LC3D09AE7

UGS : f92ee8a2d954 Catégorie :
schneider
S.D 1S ON PLATE 48V50/60 STAR DELTA

Produits associés

Options et accessoires compatibles

Autres produits associés

Voir tous les produits →
Description du produit

Contacteurs, sectionneurs, relais multifonctions Réf. f92ee8a2d954
Noter cette article

Référence :

LC3D09AE7
Marque : Schneider
Disponibilité : En Stock



LC3D09AE7
Characteristics
TeSys D
star delta starter - 3 x 3P (3 NO) - 9 A -
48 V AC coil
Main
Range TeSys
Product name TeSys D
Product or component type Star delta starter
Device short name LC3D
Contactor application Motor control
Utilisation category AC
3
Device presentation Pre
wired
Poles description 3 x 3P
Pole contact composition 3 x 3 NO
[Ue] rated operational voltage <= 690 V AC 25...400 Hz for power circuit
[Ie] rated operational current 9 A (<= 60 °C) AC AC
3 for power circuit at <= 440 V
Motor power kW 4 kW at 220/230 V AC 50/60 Hz
7.5 kW at 380/400 V AC 50/60 Hz
7.5 kW at 415 V AC 50/60 Hz
7.5 kW at 440 V AC 50/60 Hz
Control circuit type AC 50/60 Hz
Control circuit voltage 48 V AC 50/60 Hz
Auxiliary contact composition 1 NC for KM1 star contactor
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Overvoltage category III
[Ui] rated insulation voltage 690 V conforming to IEC 60947
4-1 power circuit
600 V certifications CSA power circuit
600 V certifications UL power circuit
690 V conforming to IEC 60947
1 signalling circuit
600 V certifications CSA signalling circuit
600 V certifications UL signalling circuit
Electrical durability 2 Mcycles 9 A AC
3 <= 440 V
Provided equipment Protective cover
Interlocking type Mechanical
Mounting support Plate
Jun 12, 2017
1
Disclaimer
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Standards CSA C22.2 No 14
IEC 60947
5-1
EN 60947
5-1
EN 60947
4-1
UL 508
IEC 60947
4-1
Product certifications GOST
CCC
LROS
BV
GL
UL
RINA
DNV
CSA
Complementary
Connections
terminals Screw clamp terminals for power circuit 1 1...4 mm² flexible without cable end
Screw clamp terminals for power circuit 2 1...4 mm² flexible without cable end
Screw clamp terminals for power circuit 1 1...4 mm² flexible with cable end
Screw clamp terminals for power circuit 2 1...2.5 mm² flexible with cable end
Screw clamp terminals for power circuit 1 1...4 mm² solid without cable end
Screw clamp terminals for power circuit 2 1...4 mm² solid without cable end
Screw clamp terminals for control circuit 1 1...4 mm² flexible without cable end
Screw clamp terminals for control circuit 2 1...4 mm² flexible without cable end
Screw clamp terminals for control circuit 1 1...4 mm² flexible with cable end
Screw clamp terminals for control circuit 2 1...2.5 mm² flexible with cable end
Screw clamp terminals for control circuit 1 1...4 mm² solid without cable end
Screw clamp terminals for control circuit 2 1...4 mm² solid without cable end
Tightening torque 1.7 N.m for power circuit screw clamp terminals flat Ø 6 mm
1.7 N.m for power circuit screw clamp terminals Philips No 2
1.7 N.m for control circuit screw clamp terminals flat Ø 6 mm
1.7 N.m for control circuit screw clamp terminals Philips No 2
Mechanical durability 15 Mcycles
Operating rate 30 cyc/h at <= 60 °C Starting time 30 s Coil technology Without built
in suppressor module Control circuit voltage limits 0.3...0.6 Uc at 60 °C drop-out 50/60 Hz 0.8...1.1 Uc at 60 °C operational 50 Hz 0.85...1.1 Uc at 60 °C operational 60 Hz Inrush power in VA 70 VA at 20 °C 0.75 60 Hz 70 VA at 20 °C 0.75 50 Hz Hold-in power consumption in VA 7.5 VA at 20 °C 0.3 60 Hz 7 VA at 20 °C 0.3 50 Hz Heat dissipation 2...3 W at 50/60 Hz Auxiliary contacts type Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact conforming to IEC 60947-4-1 3 x 1 NC Signalling circuit frequency 25...400 Hz Minimum switching current 5 mA for signalling circuit Switching voltage 17 V for signalling circuit Non-overlap time 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact Width 143 mm Height 124 mm Depth 143 mm Product weight 1.53 kg Environment Insulation resistance > 10 MOhm for signalling circuit
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068
2-30
Pollution degree 3
2
Ambient air temperature for storage
60...80 °C
Ambient air temperature for operation
40...70 °C at Uc
Operating altitude 3000 m without derating in temperature
Fire resistance 850 °C conforming to IEC 60695
2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
Vibrations contactor closed 4 Gn, 5...300 Hz
Shocks contactor open 10 Gn for 11 ms
Shocks contactor closed 15 Gn for 11 ms
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code
YYWW) Compliant  - since  0845  -  Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product environmental
Product end of life instructions Available
End of life manual
Contractual warranty
Warranty period 18 months
3
Product data sheet
LC3D09AE7
Dimensions Drawings
Dimensions
LC3 D09A D12A D18A D32A
a 143 143 144 165
b 26.5 26.5 26.5 32.5
c with LAD S 139 139 139 145
with LAD S and sealing cover 143 143 143 149
4
Product data sheet
LC3D09AE7
Connections and Schema
Wiring
(1) Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end).
(2) Remote control.
NOTE
LC3 D09A to D18A: Mechanical interlock between KM3 and KM1.
5
Product data sheet
LC3D09AE7
Motor Starter BOM
Our Proposal
Type 1 : Circuit Breaker + Contactor for Motor Power 7,5 kW and 415 VAC
Motor Power Icu Breaker Contactor
(kW) (kA)
7.5 15
GV2ME20 LC3D09AE7
Non contractual pictures. Type 1 coordination requires that in a short
circuit condition, the contactor or starter must not present any danger to
personnel or installations and must not be able to resume operation without repair or the replacement of parts.
6

20 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets