I/O module MES120 - Sepam series 60, 80 - 14inputs+ 6 outputs 24...250V DC

UGS : ca9a5ec5cfeb

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

59715 Marque : Schneider Disponibilité : En Stock



  • 59715
  • Characteristics
  • I/O module MES120 - Sepam series 60, 80 - 14
  • inputs+ 6 outputs 24...250V DC
  • Main
  • Module type Input/Output module
  • Range of product Sepam series 80
  • Sepam series 60
  • Device short name MES120
  • Complementary
  • Logic input number 14 : 24...250 V, limits: 19.2...275 V DC input current: 3 mA threshold tripping voltage: 14 V enhanced
  • Number of outputs 1 control relay output(s)
  • 5 annunciation relay output(s)
  • Output type Annunciation relay : 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 0.001 kA
  • cos φ > 0.3
  • Annunciation relay : 127 V DC continuous current: 2 A breaking capacity: 0.0005 kA L/R < 20 ms
  • Annunciation relay : 220 V DC continuous current: 2 A breaking capacity: 0.00015 kA L/R < 20 ms
  • Annunciation relay : 24 V DC continuous current: 2 A breaking capacity: 0.002 kA L/R < 20 ms
  • Annunciation relay : 250 V DC continuous current: 2 A breaking capacity: 0.0002 kA L/R < 20 ms
  • Annunciation relay : 48 V DC continuous current: 2 A breaking capacity: 0.001 kA L/R < 20 ms
  • Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 0.005 kA cos φ
  • > 0.3 making capacity: < 15 A for 200 ms
  • Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 0.008 kA
  • resistive making capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0002 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0005 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0007 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0001 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0002 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0003 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.004 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.006 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.008 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 250 V DC continuous current: 8 A breaking capacity: 0.0002 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.001 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.002 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.004 kA resistive making
  • capacity: < 15 A for 200 ms
  • Height 170 mm
  • Width 40 mm
  • Depth 120 mm
  • Product weight 0.38 kg
  • Mechanical robustness Earthquakes in operation ( level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
  • Earthquakes in operation ( level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
  • Jolts de-energized ( level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
  • Shocks de-energized ( level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
  • Shocks in operation ( level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
  • Vibrations de-energized ( level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
  • Vibrations in operation ( level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
  • Vibrations in operation ( level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
  • Auxiliary connection terminal Screw-type connectors 1 cable(s) 1.5 mm²
  • Screw-type connectors 1 cable(s) 2.5 mm²
  • Screw-type connectors 2 cable(s) 1 mm²
  • Screw-type connectors 1 cable(s) 0.2...2.5 mm²
  • Screw-type connectors 2 cable(s) 0.2...1 mm²
  • Environment
  • Electromagnetic compatibility 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM )
  • conforming to IEC 60255-22-1
  • 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 2.5 kV DM )
  • conforming to ANSI C37.90.1
  • 100 kHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM )
  • conforming to IEC 61000-4-12
  • Conducted disturbance emission emission tests conforming to IEC 60255-25
  • Conducted disturbance emission emission tests: A conforming to EN 55022
  • Disturbing field emission emission tests conforming to IEC 60255-25
  • Disturbing field emission emission tests: A conforming to EN 55022
  • Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 4 kV contact ) conforming to
  • ANSI C37.90.3
  • Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 6 kV contact ) conforming to
  • IEC 60255-22-2
  • Fast transient bursts immunity tests-conducted disturbances (4kV, 2.5 kHz ) conforming to ANSI
  • C37.90.1
  • Fast transient bursts immunity tests-conducted disturbances: A and B (4kV, 2.5 kHz/2 kV, 5 kHz )
  • conforming to IEC 60255-22-4
  • Fast transient bursts immunity tests-conducted disturbances: IV (4kV, 2.5 kHz ) conforming to IEC
  • 61000-4-4
  • Immunity to conducted RF disturbances immunity tests-conducted disturbances: III (10 V )
  • conforming to IEC 60255-22-6
  • Immunity to magnetic fields at network frequency immunity tests-radiated disturbances: IV (30 A/m
  • (continuous)-300 A/m (1-3 s) ) conforming to IEC 61000-4-8
  • Immunity to radiated fields immunity tests-radiated disturbances (10 V/m, 80 MHz...1 GHz )
  • conforming to IEC 60255-22-3
  • Immunity to radiated fields immunity tests-radiated disturbances (35 V/m, 25 MHz...1 GHz )
  • conforming to ANSI C37.90.2
  • Immunity to radiated fields immunity tests-radiated disturbances: III (10 V/m, 80 MHz...2 GHz )
  • conforming to IEC 61000-4-3
  • Surges immunity tests-conducted disturbances: III (2 kV CM, 1 kV DM ) conforming to IEC 61000-4-5
  • Voltage interruptions immunity tests-conducted disturbances (100 % during 100 ms ) conforming to
  • IEC 60255-11
  • Climatic withstand Exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1
  • Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2
  • Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC
  • 60068-2-78
  • Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52
  • Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02
  • conforming to IEC 60068-2-60
  • Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm
  • S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
  • 2
  • Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min
  • conforming to IEC 60068-2-14
  • Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1
  • Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2
  • Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC
  • 60068-2-78
  • Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC
  • 60068-2-30
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  0934  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • 3

Produits Similaires

Produits récemment consultés

Aucun produit récemment consulté à afficher

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

0
    0
    Votre panier
    Votre panier est videRetourner à la boutique