18642
UGS : 3467a9a96db4
Catégorie : Disjoncteurs modulaires sur rail MCB: Acti9 IC60, DPN, Domae, NG125, C120
DISJONCTEUR NG125N 3P 100A C
24.781,74DZD
UGS :
3467a9a96db4
Spécificités essentielles
Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie :
Produits associés
- Quick ViewAjouter au panier
- Quick ViewAjouter au panier
A9S70790
6.814,18DZD - Quick ViewAjouter au panier
A9S70780
5.815,94DZD
Produits liés à cet article
Référence : 18642
Marque : Schneider
Disponibilité : En Stock
- 18642
- Characteristics
- NG125 - circuit breaker - NG125N - 3P - 100A - C
- curve
- Main
- Range of product NG125
- Range Acti 9
- Product name Acti 9 NG125
- Product or component type Miniature circuit-breaker
- Device short name NG125N
- Device application Distribution
- Poles description 3P
- Number of protected poles 3
- [In] rated current 100 A at 40 °C
- Network type AC
- DC
- Trip unit technology Thermal-magnetic
- Curve code C
- Breaking capacity 10 kA Icu conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz
- 20 kA Icu conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
- 25 kA Icu conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
- 50 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
- 20 kA Icu conforming to EN/IEC 60947-2 - <= 375 V DC
- Utilisation category Category A conforming to IEC 60947-2
- Suitability for isolation Yes conforming to IEC 60947-2
- Complementary
- Network frequency 50/60 Hz
- [Ue] rated operational voltage <= 375 V DC
- 220...240 V AC 50/60 Hz
- 380...415 V AC 50/60 Hz
- 440 V AC 50/60 Hz
- 500 V AC 50/60 Hz
- Magnetic tripping limit 8 x In
- [Ics] rated service breaking capacity 37.5 kA at 75 % of breaking cap. conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- 18.75 kA at 75 % of breaking cap. conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
- 15 kA at 75 % of breaking cap. conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
- 7.5 kA at 75 % of breaking cap. conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz
- 25 kA at 100 % of breaking cap. conforming to EN/IEC 60947-2 - 375 V DC
- [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
- [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
- Contact position indicator Yes
- Control type Toggle
- Manual tripping test
- Local signalling ON/OFF indication
- Trip indicator
- Mounting mode Clip-on
- Mounting support 35 mm symmetrical DIN rail
- Comb busbar distribution block NO
- compatibility
- 9 mm pitches 9
- Height 103 mm
- Width 81 mm
- Depth 81 mm
- Product weight 0.72 kg
- Mechanical durability 20000 cycles
- Electrical durability 5000 cycles
- Provision for padlocking Padlockable
- Locking options description Integrated padlocking
- Wire stripping length 20 mm
- Tightening torque 6 N.m
- Earth-leakage protection Separate block
- Environment
- Standards EN/IEC 60947-2
- IP degree of protection IP20 conforming to IEC 60529
- IK degree of protection IK05 conforming to EN/IEC 62262
- Pollution degree 3 conforming to IEC 60947-2
- Overvoltage category IV
- Tropicalisation 2 conforming to IEC 60068-1
- Relative humidity 95 % 55 °C
- Ambient air temperature for operation -30...70 °C
- Ambient air temperature for storage -40...70 °C
- Contractual warranty
- Warranty period 18 months
- 2