Référence : 31335
Marque : Schneider
Disponibilité : En Stock
- 31335
- Characteristics
- switch-disconnector Compact INS1250 - 1250 A - 4
- poles
- Main
- Range Compact
- Product name INS1250
- Product or component type Switch disconnector
- Poles description 4P
- Network type AC
- DC
- Network frequency 50/60 Hz
- [Ie] rated operational current AC-23A : 1250 A AC 50/60 Hz 220/240 V
- AC-23A : 1250 A AC 50/60 Hz 380/415 V
- AC-23A : 1250 A AC 50/60 Hz 440/480 V
- AC-23A : 1250 A AC 50/60 Hz 500/525 V
- AC-23A : 1250 A AC 50/60 Hz 660/690 V
- AC-21A : 1250 A AC 50/60 Hz 440/480 V
- DC-21A : 1250 A DC 250 V 4 poles in series
- AC-22A : 1250 A AC 50/60 Hz 380/415 V
- DC-22A : 1250 A DC 250 V 4 poles in series
- AC-22A : 1250 A AC 50/60 Hz 480 V NEMA
- AC-21A : 1250 A AC 50/60 Hz 660/690 V
- AC-21A : 1250 A AC 50/60 Hz 220/240 V
- AC-21A : 1250 A AC 50/60 Hz 380/415 V
- AC-22A : 1250 A AC 50/60 Hz 440/480 V
- DC-22A : 1250 A DC 125 V 2 poles in series
- AC-23A : 1250 A AC 50/60 Hz 480 V NEMA
- AC-21A : 1250 A AC 50/60 Hz 480 V NEMA
- DC-23A : 1250 A DC 125 V 2 poles in series
- AC-22A : 1250 A AC 50/60 Hz 500/525 V
- AC-22A : 1250 A AC 50/60 Hz 660/690 V
- AC-21A : 1250 A AC 50/60 Hz 500/525 V
- DC-23A : 1250 A DC 250 V 4 poles in series
- AC-22A : 1250 A AC 50/60 Hz 220/240 V
- DC-21A : 1250 A DC 125 V 2 poles in series
- [Ui] rated insulation voltage 1000 V AC 50/60 Hz
- [Uimp] rated impulse withstand 12 kV
- voltage
- [Ith] conventional free air thermal 1250 A ( 60 °C )
- current
- [Icm] rated short-circuit making 75 kA 690 V AC 50/60 Hz switch-disconnector
- capacity alone
- 75 kA 690 V AC 50/60 Hz with upstream protection
- circuit breaker
- [Ue] rated operational voltage 250 V DC
- 690 V AC 50/60 Hz
- Suitability for isolation Yes
- Contact position indicator Yes
- Visible break No
- Pollution degree 3
- Complementary
- Control type Direct front rotary handle
- Handle colour Black
- Mounting mode Fixed
- Mounting support Plate
- Rail
- Upside connection Front
- Downside connection Front
- Maximum power AC-23 : 400 kW 220/240 V AC 50/60 Hz
- AC-23 : 900 kW 500/525 V AC 50/60 Hz
- 1 / 2
- The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
- This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
- It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
- Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
- AC-23 : 710 kW 380/400 V AC 50/60 Hz
- AC-23 : 800 kW 415 V AC 50/60 Hz
- Rated duty Uninterrupted
- Intermittent duty class Class 120 - 60 %
- [Icw] rated short-time withstand current 10 kA ( 20 s ) conforming to IEC 60947-3
- 20 kA ( 3 s ) conforming to IEC 60947-3
- 35 kA ( 1 s ) conforming to IEC 60947-3
- 42 kA ( 0.8 s ) conforming to IEC 60947-3
- 50 kA ( 0.5 s ) conforming to IEC 60947-3
- 8 kA ( 30 s ) conforming to IEC 60947-3
- Mechanical durability 3000 cycles
- Electrical durability DC-21A : 500 cycles 250 V DC 4 poles in series
- AC-21A : 500 cycles 220/240 V AC 50/60 Hz
- AC-21A : 500 cycles 380/415 V AC 50/60 Hz
- AC-21A : 500 cycles 440/480 V AC 50/60 Hz
- AC-21A : 500 cycles 480 V AC 50/60 Hz conforming to NEMA
- AC-21A : 500 cycles 500/525 V AC 50/60 Hz
- AC-21A : 500 cycles 660/690 V AC 50/60 Hz
- AC-22A : 500 cycles 220/240 V AC 50/60 Hz
- AC-22A : 500 cycles 380/415 V AC 50/60 Hz
- AC-22A : 500 cycles 440/480 V AC 50/60 Hz
- AC-22A : 500 cycles 480 V AC 50/60 Hz conforming to NEMA
- AC-22A : 500 cycles 500/525 V AC 50/60 Hz
- AC-22A : 500 cycles 660/690 V AC 50/60 Hz
- AC-23A : 500 cycles 220/240 V AC 50/60 Hz
- AC-23A : 500 cycles 380/415 V AC 50/60 Hz
- AC-23A : 500 cycles 440/480 V AC 50/60 Hz
- AC-23A : 500 cycles 480 V AC 50/60 Hz conforming to NEMA
- AC-23A : 500 cycles 500/525 V AC 50/60 Hz
- AC-23A : 500 cycles 660/690 V AC 50/60 Hz
- DC-21A : 500 cycles 125 V DC 2 poles in series
- DC-22A : 500 cycles 125 V DC 2 poles in series
- DC-22A : 500 cycles 250 V DC 4 poles in series
- DC-23A : 500 cycles 125 V DC 2 poles in series
- DC-23A : 500 cycles 250 V DC 4 poles in series
- Connection pitch 70 mm
- Height 300 mm
- Width 410 mm
- Depth 146.5 mm
- Product weight 18 kg
- Environment
- standards IEC 60947-1
- IEC 60947-3
- product certifications KEMA-KEUR
- IP degree of protection IP40 conforming to IEC 60529
- IK degree of protection IK07 conforming to EN 50102
- ambient air temperature for operation -25...70 °C
- ambient air temperature for storage -50...85 °C
- Contractual warranty
- Warranty period 18 months