- Characteristics
- base unit SEP888 for Sepam series 80 - 24…250
- V - with mimic-based UMI
- Main
- Range of product Sepam series 80
- Device short name SEP888
- User machine interface type Mimic-based
- Complementary
- UMI indication Alarms and operating messages
- List of activated protection functions
- Logipam data
- Main protection settings
- Phasor diagram of currents or voltages
- Status of logic inputs
- Switchgear status on the animated mimic diagram
- Version of Sepam and remote modules
- Metering and diagnosis data
- UMI control Alarm acknowledgement
- Device open/close order
- Output testing
- Selection of Sepam control mode
- Sepam reset
- Display resolution 128 x 240 pixels
- Number of key 14
- Local signalling 2 LEDs for Sepam operating status on back part
- 2 LEDs for Sepam operating status on front face
- 9 LEDs for indication of parameters on front face
- Output type Annunciation relay : 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms
- Annunciation relay : 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms
- Annunciation relay : 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms
- Annunciation relay : 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms
- Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 8 A resistive
- making capacity: < 15 A for 200 ms
- Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making
- capacity: < 15 A for 200 ms
- Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making
- capacity: < 15 A for 200 ms
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity:
- < 15 A for 200 ms
- Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making
- capacity: < 15 A for 200 ms
- Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making
- capacity: < 15 A for 200 ms
- Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity:
- < 15 A for 200 ms
- Control relay : 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity:
- < 15 A for 200 ms
- Control relay : 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity:
- < 15 A for 200 ms
- Control relay : 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: <
- 15 A for 200 ms
- Control relay : 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity:
- < 15 A for 200 ms
- Control relay : 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity:
- < 15 A for 200 ms
- Control relay : 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: <
- 15 A for 200 ms
- Annunciation relay : 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 1 A cos
- φ > 0.3
- Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 5 A cos φ >
- 0.3 making capacity: < 15 A for 200 ms
- [Us] rated supply voltage 24/250 V DC tolerance: - 20...10 % maximum consumption: < 16 W
- Supply inrush current < 10 A for 10 ms at 24/250 V DC
- Battery type Lithium 3.6 V size: 1/2 AA
- Battery life 10 yr with Sepam energized
- 8 yr with Sepam not energized
- Mounting mode Fixed
- Mounting support Plate
- Height 222 mm
- Width 264 mm
- Depth 89.7 mm
- Product weight 4.22 kg
- Power frequency dielectric withstand 1 kV (indication output) during 1 min conforming to ANSI C37.90
- 1.5 kV (control output) during 1 min conforming to ANSI C37.90
- 2 kV during 1 min conforming to IEC 60255-5
- [Uimp] rated impulse withstand voltage 5 kV (1.2/50 µs) conforming to IEC 60255-5
- Mechanical robustness Earthquakes in operation ( level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
- Earthquakes in operation ( level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
- Jolts de-energized ( level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
- Shocks de-energized ( level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
- Shocks in operation ( level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
- Vibrations de-energized ( level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
- Vibrations in operation ( level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
- Vibrations in operation ( level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
- Environment
- Standards CSA C22.2 No 0.17-00
- CSA C22.2 No 14-95
- CSA C22.2 No 94-M91
- EN 50263
- UL 508
- Product certifications C22.2 file N° 210625
- CE
- UL 508 file N° 212533
- Fire resistance 650 °C conforming to IEC 60695-2-11
- IP degree of protection IP20 conforming to IEC 60529 other panels
- IP52 conforming to IEC 60529 front panel
- NEMA degree of protection Type 12 conforming to NEMA
- Immunity to microbreaks 100 ms
- Electromagnetic compatibility Fast transient bursts immunity tests-conducted disturbances : IV (4kV, 2.5 kHz ) conforming to IEC
- 61000-4-4
- Immunity to magnetic fields at network frequency immunity tests-radiated disturbances : IV (30 A/m
- (continuous)-300 A/m (13 s) ) conforming to IEC 61000-4-8
- 2
- Immunity to radiated fields immunity tests-radiated disturbances : III (10 V/m, 80 MHz...2 GHz )
- conforming to IEC 61000-4-3
- Disturbing field emission emission tests : A conforming to EN 55022
- Fast transient bursts immunity tests-conducted disturbances : A and B (4kV, 2.5 kHz/2 kV, 5 kHz )
- conforming to IEC 60255-22-4
- Immunity to conducted RF disturbances immunity tests-conducted disturbances : III (10 V )
- conforming to IEC 60255-22-6
- Surges immunity tests-conducted disturbances : III (2 kV CM, 1 kV MD ) conforming to IEC
- 61000-4-5
- Conducted disturbance emission emission tests : A conforming to EN 55022
- 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV MD )
- conforming to IEC 60255-22-1
- 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 2.5 kV MD )
- conforming to ANSI C37.90.1
- 100 kHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV MD )
- conforming to IEC 61000-4-12
- Conducted disturbance emission emission tests conforming to IEC 60255-25
- Disturbing field emission emission tests conforming to IEC 60255-25
- Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 4 kV contact ) conforming to
- ANSI C37.90.3
- Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 6 kV contact ) conforming to
- IEC 60255-22-2
- Fast transient bursts immunity tests-conducted disturbances (4kV, 2.5 kHz ) conforming to ANSI
- C37.90.1
- Immunity to radiated fields immunity tests-radiated disturbances (10 V/m, 80 MHz...1 GHz )
- conforming to IEC 60255-22-3
- Immunity to radiated fields immunity tests-radiated disturbances (35 V/m, 25 MHz...1 GHz )
- conforming to ANSI C37.90.2
- Voltage interruptions immunity tests-conducted disturbances (100 % during 100 ms ) conforming to
- IEC 60255-11
- Climatic withstand Continuous exposure to damp heat (in operation) : Cab : 10 days, 93 % RH, 40 °C conforming to IEC
- 60068-2-78
- Continuous exposure to damp heat (in storage) : Cab : 56 days, 93 % RH, 40 °C conforming to IEC
- 60068-2-78
- Continuous exposure to damp heat (in storage) : Db : 6 days, 95 % RH, 55 °C conforming to IEC
- 60068-2-30
- Exposure to cold (in operation) : Ad : - 25 °C conforming to IEC 60068-2-1
- Exposure to cold (in storage) : Ab : - 25 °C conforming to IEC 60068-2-1
- Exposure to dry heat (in operation) : Bd : 70 °C conforming to IEC 60068-2-2
- Exposure to dry heat (in storage) : Bb : 70 °C conforming to IEC 60068-2-2
- Salt mist (in operation) : Kb/2 : 6 days conforming to IEC 60068-2-52
- Temperature variation with specified variation rate (in storage) : Nb : - 25 °C to 70 °C, 5 °C/min
- conforming to IEC 60068-2-14
- Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02
- conforming to IEC 60068-2-60
- Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm
- S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
- Offer Sustainability
- Sustainable offer status Green Premium product
- RoHS (date code: YYWW) Compliant - since 1029 - Schneider Electric declaration of conformity
- Schneider Electric declaration of conformity
- REACh Reference not containing SVHC above the threshold
- Reference not containing SVHC above the threshold
- Product environmental profile Available
- Product end of life instructions Available
- 3
Produits Similaires
Produits similaires
-
03250
Ajouter au panier Aperçu Ajouter au panier -
14882
Ajouter au panier Aperçu Ajouter au panier -
03238
Ajouter au panier Aperçu Ajouter au panier -
13409
Ajouter au panier Aperçu Ajouter au panier
Produits récemment consultés
Aucun produit récemment consulté à afficher