base unit SEP888 for Sepam series 80 - 24…250V - with mimic-based UMI

- quantité- + quantité+
UGS : 7a2840144e35

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

59705 Marque : Schneider Disponibilité : En Stock



  • 59705
  • Characteristics
  • base unit SEP888 for Sepam series 80 - 24…250
  • V - with mimic-based UMI
  • Main
  • Range of product Sepam series 80
  • Device short name SEP888
  • User machine interface type Mimic-based
  • Complementary
  • UMI indication Alarms and operating messages
  • List of activated protection functions
  • Logipam data
  • Main protection settings
  • Phasor diagram of currents or voltages
  • Status of logic inputs
  • Switchgear status on the animated mimic diagram
  • Version of Sepam and remote modules
  • Metering and diagnosis data
  • UMI control Alarm acknowledgement
  • Device open/close order
  • Output testing
  • Selection of Sepam control mode
  • Sepam reset
  • Display resolution 128 x 240 pixels
  • Number of key 14
  • Local signalling 2 LEDs for Sepam operating status on back part
  • 2 LEDs for Sepam operating status on front face
  • 9 LEDs for indication of parameters on front face
  • Output type Annunciation relay : 127 V DC continuous current: 2 A breaking capacity: 0.5 A L/R < 20 ms
  • Annunciation relay : 220 V DC continuous current: 2 A breaking capacity: 0.15 A L/R < 20 ms
  • Annunciation relay : 24 V DC continuous current: 2 A breaking capacity: 2 A L/R < 20 ms
  • Annunciation relay : 48 V DC continuous current: 2 A breaking capacity: 1 A L/R < 20 ms
  • Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 8 A resistive
  • making capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.5 A L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.7 A resistive making capacity:
  • < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.1 A L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.2 A L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.3 A resistive making capacity:
  • < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 4 A L/R < 40 ms making capacity:
  • < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 6 A L/R < 20 ms making capacity:
  • < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 8 A resistive making capacity: <
  • 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 1 A L/R < 40 ms making capacity:
  • < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 2 A L/R < 20 ms making capacity:
  • < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 4 A resistive making capacity: <
  • 15 A for 200 ms
  • Annunciation relay : 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 1 A cos
  • φ > 0.3
  • Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 5 A cos φ >
  • 0.3 making capacity: < 15 A for 200 ms
  • [Us] rated supply voltage 24/250 V DC tolerance: - 20...10 % maximum consumption: < 16 W
  • Supply inrush current < 10 A for 10 ms at 24/250 V DC
  • Battery type Lithium 3.6 V size: 1/2 AA
  • Battery life 10 yr with Sepam energized
  • 8 yr with Sepam not energized
  • Mounting mode Fixed
  • Mounting support Plate
  • Height 222 mm
  • Width 264 mm
  • Depth 89.7 mm
  • Product weight 4.22 kg
  • Power frequency dielectric withstand 1 kV (indication output) during 1 min conforming to ANSI C37.90
  • 1.5 kV (control output) during 1 min conforming to ANSI C37.90
  • 2 kV during 1 min conforming to IEC 60255-5
  • [Uimp] rated impulse withstand voltage 5 kV (1.2/50 µs) conforming to IEC 60255-5
  • Mechanical robustness Earthquakes in operation ( level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
  • Earthquakes in operation ( level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
  • Jolts de-energized ( level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
  • Shocks de-energized ( level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
  • Shocks in operation ( level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
  • Vibrations de-energized ( level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
  • Vibrations in operation ( level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
  • Vibrations in operation ( level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
  • Environment
  • Standards CSA C22.2 No 0.17-00
  • CSA C22.2 No 14-95
  • CSA C22.2 No 94-M91
  • EN 50263
  • UL 508
  • Product certifications C22.2 file N° 210625
  • CE
  • UL 508 file N° 212533
  • Fire resistance 650 °C conforming to IEC 60695-2-11
  • IP degree of protection IP20 conforming to IEC 60529 other panels
  • IP52 conforming to IEC 60529 front panel
  • NEMA degree of protection Type 12 conforming to NEMA
  • Immunity to microbreaks 100 ms
  • Electromagnetic compatibility Fast transient bursts immunity tests-conducted disturbances : IV (4kV, 2.5 kHz ) conforming to IEC
  • 61000-4-4
  • Immunity to magnetic fields at network frequency immunity tests-radiated disturbances : IV (30 A/m
  • (continuous)-300 A/m (13 s) ) conforming to IEC 61000-4-8
  • 2
  • Immunity to radiated fields immunity tests-radiated disturbances : III (10 V/m, 80 MHz...2 GHz )
  • conforming to IEC 61000-4-3
  • Disturbing field emission emission tests : A conforming to EN 55022
  • Fast transient bursts immunity tests-conducted disturbances : A and B (4kV, 2.5 kHz/2 kV, 5 kHz )
  • conforming to IEC 60255-22-4
  • Immunity to conducted RF disturbances immunity tests-conducted disturbances : III (10 V )
  • conforming to IEC 60255-22-6
  • Surges immunity tests-conducted disturbances : III (2 kV CM, 1 kV MD ) conforming to IEC
  • 61000-4-5
  • Conducted disturbance emission emission tests : A conforming to EN 55022
  • 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV MD )
  • conforming to IEC 60255-22-1
  • 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 2.5 kV MD )
  • conforming to ANSI C37.90.1
  • 100 kHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV MD )
  • conforming to IEC 61000-4-12
  • Conducted disturbance emission emission tests conforming to IEC 60255-25
  • Disturbing field emission emission tests conforming to IEC 60255-25
  • Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 4 kV contact ) conforming to
  • ANSI C37.90.3
  • Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 6 kV contact ) conforming to
  • IEC 60255-22-2
  • Fast transient bursts immunity tests-conducted disturbances (4kV, 2.5 kHz ) conforming to ANSI
  • C37.90.1
  • Immunity to radiated fields immunity tests-radiated disturbances (10 V/m, 80 MHz...1 GHz )
  • conforming to IEC 60255-22-3
  • Immunity to radiated fields immunity tests-radiated disturbances (35 V/m, 25 MHz...1 GHz )
  • conforming to ANSI C37.90.2
  • Voltage interruptions immunity tests-conducted disturbances (100 % during 100 ms ) conforming to
  • IEC 60255-11
  • Climatic withstand Continuous exposure to damp heat (in operation) : Cab : 10 days, 93 % RH, 40 °C conforming to IEC
  • 60068-2-78
  • Continuous exposure to damp heat (in storage) : Cab : 56 days, 93 % RH, 40 °C conforming to IEC
  • 60068-2-78
  • Continuous exposure to damp heat (in storage) : Db : 6 days, 95 % RH, 55 °C conforming to IEC
  • 60068-2-30
  • Exposure to cold (in operation) : Ad : - 25 °C conforming to IEC 60068-2-1
  • Exposure to cold (in storage) : Ab : - 25 °C conforming to IEC 60068-2-1
  • Exposure to dry heat (in operation) : Bd : 70 °C conforming to IEC 60068-2-2
  • Exposure to dry heat (in storage) : Bb : 70 °C conforming to IEC 60068-2-2
  • Salt mist (in operation) : Kb/2 : 6 days conforming to IEC 60068-2-52
  • Temperature variation with specified variation rate (in storage) : Nb : - 25 °C to 70 °C, 5 °C/min
  • conforming to IEC 60068-2-14
  • Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02
  • conforming to IEC 60068-2-60
  • Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm
  • S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1029  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Available
  • 3

Produits Similaires

Produits récemment consultés

Aucun produit récemment consulté à afficher

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

0
    0
    Votre panier
    Votre panier est videRetourner à la boutique