UGS : ca9a5ec5cfeb Catégorie :
I/O module MES120 - Sepam series 60, 80 - 14inputs+ 6 outputs 24...250V DC

UGS : ca9a5ec5cfeb

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

59715 Marque : Schneider Disponibilité : En Stock



  • 59715
  • Characteristics
  • I/O module MES120 - Sepam series 60, 80 - 14
  • inputs+ 6 outputs 24...250V DC
  • Main
  • Module type Input/Output module
  • Range of product Sepam series 80
  • Sepam series 60
  • Device short name MES120
  • Complementary
  • Logic input number 14 : 24...250 V, limits: 19.2...275 V DC input current: 3 mA threshold tripping voltage: 14 V enhanced
  • Number of outputs 1 control relay output(s)
  • 5 annunciation relay output(s)
  • Output type Annunciation relay : 100...240 V AC 47.5...63 Hz continuous current: 2 A breaking capacity: 0.001 kA
  • cos φ > 0.3
  • Annunciation relay : 127 V DC continuous current: 2 A breaking capacity: 0.0005 kA L/R < 20 ms
  • Annunciation relay : 220 V DC continuous current: 2 A breaking capacity: 0.00015 kA L/R < 20 ms
  • Annunciation relay : 24 V DC continuous current: 2 A breaking capacity: 0.002 kA L/R < 20 ms
  • Annunciation relay : 250 V DC continuous current: 2 A breaking capacity: 0.0002 kA L/R < 20 ms
  • Annunciation relay : 48 V DC continuous current: 2 A breaking capacity: 0.001 kA L/R < 20 ms
  • Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 0.005 kA cos φ
  • > 0.3 making capacity: < 15 A for 200 ms
  • Control relay : 100...240 V AC 47.5...63 Hz continuous current: 8 A breaking capacity: 0.008 kA
  • resistive making capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0002 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0005 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 127 V DC continuous current: 8 A breaking capacity: 0.0007 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0001 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0002 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 220 V DC continuous current: 8 A breaking capacity: 0.0003 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.004 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.006 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Control relay : 24 V DC continuous current: 8 A breaking capacity: 0.008 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 250 V DC continuous current: 8 A breaking capacity: 0.0002 kA resistive making
  • capacity: < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.001 kA L/R < 40 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.002 kA L/R < 20 ms making
  • capacity: < 15 A for 200 ms
  • Control relay : 48 V DC continuous current: 8 A breaking capacity: 0.004 kA resistive making
  • capacity: < 15 A for 200 ms
  • Height 170 mm
  • Width 40 mm
  • Depth 120 mm
  • Product weight 0.38 kg
  • Mechanical robustness Earthquakes in operation ( level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
  • Earthquakes in operation ( level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
  • Jolts de-energized ( level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
  • Shocks de-energized ( level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2
  • Shocks in operation ( level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
  • Vibrations de-energized ( level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
  • Vibrations in operation ( level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
  • Vibrations in operation ( level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
  • Auxiliary connection terminal Screw-type connectors 1 cable(s) 1.5 mm²
  • Screw-type connectors 1 cable(s) 2.5 mm²
  • Screw-type connectors 2 cable(s) 1 mm²
  • Screw-type connectors 1 cable(s) 0.2...2.5 mm²
  • Screw-type connectors 2 cable(s) 0.2...1 mm²
  • Environment
  • Electromagnetic compatibility 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM )
  • conforming to IEC 60255-22-1
  • 1 MHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 2.5 kV DM )
  • conforming to ANSI C37.90.1
  • 100 kHz damped oscillating wave immunity tests-conducted disturbances (2.5 kV CM, 1 kV DM )
  • conforming to IEC 61000-4-12
  • Conducted disturbance emission emission tests conforming to IEC 60255-25
  • Conducted disturbance emission emission tests: A conforming to EN 55022
  • Disturbing field emission emission tests conforming to IEC 60255-25
  • Disturbing field emission emission tests: A conforming to EN 55022
  • Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 4 kV contact ) conforming to
  • ANSI C37.90.3
  • Electrostatic discharge immunity tests-radiated disturbances (8 kV air, 6 kV contact ) conforming to
  • IEC 60255-22-2
  • Fast transient bursts immunity tests-conducted disturbances (4kV, 2.5 kHz ) conforming to ANSI
  • C37.90.1
  • Fast transient bursts immunity tests-conducted disturbances: A and B (4kV, 2.5 kHz/2 kV, 5 kHz )
  • conforming to IEC 60255-22-4
  • Fast transient bursts immunity tests-conducted disturbances: IV (4kV, 2.5 kHz ) conforming to IEC
  • 61000-4-4
  • Immunity to conducted RF disturbances immunity tests-conducted disturbances: III (10 V )
  • conforming to IEC 60255-22-6
  • Immunity to magnetic fields at network frequency immunity tests-radiated disturbances: IV (30 A/m
  • (continuous)-300 A/m (1-3 s) ) conforming to IEC 61000-4-8
  • Immunity to radiated fields immunity tests-radiated disturbances (10 V/m, 80 MHz...1 GHz )
  • conforming to IEC 60255-22-3
  • Immunity to radiated fields immunity tests-radiated disturbances (35 V/m, 25 MHz...1 GHz )
  • conforming to ANSI C37.90.2
  • Immunity to radiated fields immunity tests-radiated disturbances: III (10 V/m, 80 MHz...2 GHz )
  • conforming to IEC 61000-4-3
  • Surges immunity tests-conducted disturbances: III (2 kV CM, 1 kV DM ) conforming to IEC 61000-4-5
  • Voltage interruptions immunity tests-conducted disturbances (100 % during 100 ms ) conforming to
  • IEC 60255-11
  • Climatic withstand Exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1
  • Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2
  • Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC
  • 60068-2-78
  • Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52
  • Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02
  • conforming to IEC 60068-2-60
  • Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm
  • S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60
  • 2
  • Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min
  • conforming to IEC 60068-2-14
  • Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1
  • Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2
  • Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC
  • 60068-2-78
  • Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC
  • 60068-2-30
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  0934  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    NSYZZ5104
    NSYZZ5104
    1 X 86.249,69DZD = 86.249,69DZD
    SR3B261FU
    SR3B261FU
    1 X 39.051,26DZD = 39.051,26DZD
    schneider
    ZC4GM4
    1 X 12.574,63DZD = 12.574,63DZD
    ZL1AA12
    ZL1AA12
    1 X 27.398,58DZD = 27.398,58DZD
    ZCY91
    ZCY91
    1 X 1.194,48DZD = 1.194,48DZD
    9001KP40A9
    9001KP40A9
    1 X 5.540,70DZD = 5.540,70DZD
    MVS08N3MW2V
    MVS08N3MW2V
    1 X 696.195,74DZD = 696.195,74DZD
    STBXMP5600
    STBXMP5600
    1 X 5.300,38DZD = 5.300,38DZD
    MGU6.002.874
    MGU6.002.874
    1 X 641,38DZD = 641,38DZD