substation - S84 - Sepam series 80Main

UGS : ee4189933f15

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

59732 Marque : Schneider Disponibilité : En Stock



  • 59732
  • Characteristics
  • substation - S84 - Sepam series 80
  • Main
  • Relay application Substation
  • Range of product Sepam series 80
  • Sepam series 80 NPP
  • Device short name S84
  • Control and monitoring type Circuit breaker/contactor control ANSI code: 94/69 ( option )
  • Latching/Acknowledgement ANSI code: 86
  • Logic discrimination ANSI code: 68 ( option )
  • Switching of groups of settings
  • Annunciation ANSI code: 30
  • Automatic transfer (AT) ( option )
  • Logipam programming (ladder language) ( option )
  • Logic equation editor 200 operators
  • Metering type Measured residual current I0, calculated I'0∑
  • Positive sequence voltage Vd/rotation direction
  • Frequency
  • Calculated active and reactive energy (+/- W.h, +/- VAR.h)
  • Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) ( option )
  • Phase current I1, I2, I3 RMS
  • Demand current I1, I2, I3
  • Peak demand current IM1, IM2, IM3
  • Measured residual current I'0
  • Voltage U21, U32, U13, V1, V2, V3
  • Residual voltage V0
  • Negative sequence voltage Vi
  • Active power P, P1, P2, P3
  • Reactive power Q, Q1, Q2, Q3
  • Apparent power S, S1, S2, S3
  • Peak demand power PM, QM
  • Power factor
  • Network and machine diagnosis type Datalog (DLG)
  • Unbalance ratio/negative sequence current Ii
  • Disturbance recording
  • Thermal capacity used
  • Remaining operating time before overload tripping
  • Waiting time after overload tripping
  • Tripping context
  • Phase fault and earth fault trip counters
  • Harmonic distortion (THD), current and voltage Ithd, Uthd
  • Difference in amplitude, frequency and phase of voltages with synchro-check ( option )
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Apparent positive sequence impedance Zd
  • Apparent phase-to-phase impedances Z21, Z32, Z13
  • Phase displacement
  • Switchgear diagnosis type CT/VT supervision ANSI code: 60FL
  • Trip circuit supervision ANSI code: 74 ( option )
  • Auxiliary power supply monitoring
  • Nb of operations, operating time, charging time, nb of racking out operations ( option )
  • Cumulative breaking current
  • Complementary
  • Type of measurement Peak demand power
  • Energy
  • Power (P,Q)
  • Voltage
  • Frequency
  • Power factor
  • Current
  • Protection type Directional active underpower  ANSI code:  37P
  • Rate of change of frequency  ANSI code:  81R
  • Directional earth fault ANSI code: 67N/67NC
  • Directional phase overcurrent ANSI code: 67
  • Synchro-check ( option ) ANSI code: 25
  • Overvoltage (L-L or L-N) ANSI code: 59
  • Thermal overload for cables ANSI code: 49RMS
  • Earth fault/sensitive earth fault ANSI code: 50N/51N
  • Earth fault/sensitive earth fault ANSI code: 50G/51G
  • Negative sequence/unbalance ANSI code: 46
  • Remanent undervoltage ANSI code: 27R
  • Overfrequency ANSI code: 81H
  • Underfrequency ANSI code: 81L
  • Negative sequence overvoltage ANSI code: 47
  • Directional active overpower ANSI code: 32P
  • Positive sequence undercurrent ANSI code: 27D
  • Undervoltage (L-L or L-N) ANSI code: 27
  • Breaker failure ANSI code: 50BF
  • Neutral voltage displacement ANSI code: 59N
  • Phase overcurrent ANSI code: 50/51
  • Recloser (4 cycles) ( option ) ANSI code: 79
  • Communication port protocol Measurement readout ( option ) : Modbus
  • Remote control orders ( option ) : Modbus
  • Remote indication and time tagging of events ( option ) : Modbus
  • Remote protection setting ( option ) : Modbus
  • Transfer of disturbance recording data ( option ) : Modbus
  • Input output max capacity 42 inputs + 23 outputs
  • Communication compatibility Modbus RTU
  • DNP3
  • IEC 61850
  • IEC 60870-5-103
  • IEC 61850 goose message
  • Modbus TCPIP
  • User machine interface type Advanced
  • Remote
  • Without
  • Mimic-based
  • 2

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

12
    12
    Votre panier
    18604
    18604
    1 X 58.280,76DZD = 58.280,76DZD
    33469
    33469
    1 X 278.698,70DZD = 278.698,70DZD
    CA2KN22U72
    CA2KN22U72
    1 X 4.743,75DZD = 4.743,75DZD
    NSYEC126
    NSYEC126
    1 X 12.359,12DZD = 12.359,12DZD
    XS9E111A2L5
    XS9E111A2L5
    1 X 17.404,36DZD = 17.404,36DZD
    LV429172
    LV429172
    1 X 30.398,35DZD = 30.398,35DZD
    A9L16292
    A9L16292
    1 X 21.612,63DZD = 21.612,63DZD
    XC1AC117
    XC1AC117
    1 X 28.730,12DZD = 28.730,12DZD
    33466
    33466
    1 X 269.932,95DZD = 269.932,95DZD
    CA2KN22FE7
    CA2KN22FE7
    1 X 3.788,71DZD = 3.788,71DZD
    CA2KN22V7
    CA2KN22V7
    1 X 4.085,86DZD = 4.085,86DZD
    08359
    08359
    1 X 43.168,65DZD = 43.168,65DZD