substation - S84 - Sepam series 80Main

UGS : ee4189933f15

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

59732 Marque : Schneider Disponibilité : En Stock



  • 59732
  • Characteristics
  • substation - S84 - Sepam series 80
  • Main
  • Relay application Substation
  • Range of product Sepam series 80
  • Sepam series 80 NPP
  • Device short name S84
  • Control and monitoring type Circuit breaker/contactor control ANSI code: 94/69 ( option )
  • Latching/Acknowledgement ANSI code: 86
  • Logic discrimination ANSI code: 68 ( option )
  • Switching of groups of settings
  • Annunciation ANSI code: 30
  • Automatic transfer (AT) ( option )
  • Logipam programming (ladder language) ( option )
  • Logic equation editor 200 operators
  • Metering type Measured residual current I0, calculated I'0∑
  • Positive sequence voltage Vd/rotation direction
  • Frequency
  • Calculated active and reactive energy (+/- W.h, +/- VAR.h)
  • Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) ( option )
  • Phase current I1, I2, I3 RMS
  • Demand current I1, I2, I3
  • Peak demand current IM1, IM2, IM3
  • Measured residual current I'0
  • Voltage U21, U32, U13, V1, V2, V3
  • Residual voltage V0
  • Negative sequence voltage Vi
  • Active power P, P1, P2, P3
  • Reactive power Q, Q1, Q2, Q3
  • Apparent power S, S1, S2, S3
  • Peak demand power PM, QM
  • Power factor
  • Network and machine diagnosis type Datalog (DLG)
  • Unbalance ratio/negative sequence current Ii
  • Disturbance recording
  • Thermal capacity used
  • Remaining operating time before overload tripping
  • Waiting time after overload tripping
  • Tripping context
  • Phase fault and earth fault trip counters
  • Harmonic distortion (THD), current and voltage Ithd, Uthd
  • Difference in amplitude, frequency and phase of voltages with synchro-check ( option )
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Apparent positive sequence impedance Zd
  • Apparent phase-to-phase impedances Z21, Z32, Z13
  • Phase displacement
  • Switchgear diagnosis type CT/VT supervision ANSI code: 60FL
  • Trip circuit supervision ANSI code: 74 ( option )
  • Auxiliary power supply monitoring
  • Nb of operations, operating time, charging time, nb of racking out operations ( option )
  • Cumulative breaking current
  • Complementary
  • Type of measurement Peak demand power
  • Energy
  • Power (P,Q)
  • Voltage
  • Frequency
  • Power factor
  • Current
  • Protection type Directional active underpower  ANSI code:  37P
  • Rate of change of frequency  ANSI code:  81R
  • Directional earth fault ANSI code: 67N/67NC
  • Directional phase overcurrent ANSI code: 67
  • Synchro-check ( option ) ANSI code: 25
  • Overvoltage (L-L or L-N) ANSI code: 59
  • Thermal overload for cables ANSI code: 49RMS
  • Earth fault/sensitive earth fault ANSI code: 50N/51N
  • Earth fault/sensitive earth fault ANSI code: 50G/51G
  • Negative sequence/unbalance ANSI code: 46
  • Remanent undervoltage ANSI code: 27R
  • Overfrequency ANSI code: 81H
  • Underfrequency ANSI code: 81L
  • Negative sequence overvoltage ANSI code: 47
  • Directional active overpower ANSI code: 32P
  • Positive sequence undercurrent ANSI code: 27D
  • Undervoltage (L-L or L-N) ANSI code: 27
  • Breaker failure ANSI code: 50BF
  • Neutral voltage displacement ANSI code: 59N
  • Phase overcurrent ANSI code: 50/51
  • Recloser (4 cycles) ( option ) ANSI code: 79
  • Communication port protocol Measurement readout ( option ) : Modbus
  • Remote control orders ( option ) : Modbus
  • Remote indication and time tagging of events ( option ) : Modbus
  • Remote protection setting ( option ) : Modbus
  • Transfer of disturbance recording data ( option ) : Modbus
  • Input output max capacity 42 inputs + 23 outputs
  • Communication compatibility Modbus RTU
  • DNP3
  • IEC 61850
  • IEC 60870-5-103
  • IEC 61850 goose message
  • Modbus TCPIP
  • User machine interface type Advanced
  • Remote
  • Without
  • Mimic-based
  • 2

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

15
    15
    Votre panier
    140CPU31110
    140CPU31110
    1 X 0,00DZD = 0,00DZD
    TRV00870
    TRV00870
    1 X 9.386,85DZD = 9.386,85DZD
    03252
    03252
    1 X 0,00DZD = 0,00DZD
    XC1AC117
    XC1AC117
    1 X 28.730,12DZD = 28.730,12DZD
    01033
    01033
    1 X 28.293,02DZD = 28.293,02DZD
    9001KP40A9
    9001KP40A9
    1 X 5.540,70DZD = 5.540,70DZD
    AB1GE
    AB1GE
    1 X 56,14DZD = 56,14DZD
    ABS2SC01EB
    ABS2SC01EB
    1 X 10.317,05DZD = 10.317,05DZD
    KBA25ED2303W
    KBA25ED2303W
    1 X 10.624,64DZD = 10.624,64DZD
    1469540000
    1469540000
    1 X 23.380,00DZD = 23.380,00DZD
    15336
    15336
    1 X 6.178,95DZD = 6.178,95DZD
    09948
    09948
    1 X 3.892,56DZD = 3.892,56DZD
    TRV00880
    TRV00880
    1 X 5.930,02DZD = 5.930,02DZD
    KBA40ED4303W
    KBA40ED4303W
    1 X 16.413,74DZD = 16.413,74DZD
    13409
    13409
    1 X 0,00DZD = 0,00DZD