UGS : ee4189933f15 Catégorie :
substation - S84 - Sepam series 80Main

UGS : ee4189933f15

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

59732 Marque : Schneider Disponibilité : En Stock



  • 59732
  • Characteristics
  • substation - S84 - Sepam series 80
  • Main
  • Relay application Substation
  • Range of product Sepam series 80
  • Sepam series 80 NPP
  • Device short name S84
  • Control and monitoring type Circuit breaker/contactor control ANSI code: 94/69 ( option )
  • Latching/Acknowledgement ANSI code: 86
  • Logic discrimination ANSI code: 68 ( option )
  • Switching of groups of settings
  • Annunciation ANSI code: 30
  • Automatic transfer (AT) ( option )
  • Logipam programming (ladder language) ( option )
  • Logic equation editor 200 operators
  • Metering type Measured residual current I0, calculated I'0∑
  • Positive sequence voltage Vd/rotation direction
  • Frequency
  • Calculated active and reactive energy (+/- W.h, +/- VAR.h)
  • Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) ( option )
  • Phase current I1, I2, I3 RMS
  • Demand current I1, I2, I3
  • Peak demand current IM1, IM2, IM3
  • Measured residual current I'0
  • Voltage U21, U32, U13, V1, V2, V3
  • Residual voltage V0
  • Negative sequence voltage Vi
  • Active power P, P1, P2, P3
  • Reactive power Q, Q1, Q2, Q3
  • Apparent power S, S1, S2, S3
  • Peak demand power PM, QM
  • Power factor
  • Network and machine diagnosis type Datalog (DLG)
  • Unbalance ratio/negative sequence current Ii
  • Disturbance recording
  • Thermal capacity used
  • Remaining operating time before overload tripping
  • Waiting time after overload tripping
  • Tripping context
  • Phase fault and earth fault trip counters
  • Harmonic distortion (THD), current and voltage Ithd, Uthd
  • Difference in amplitude, frequency and phase of voltages with synchro-check ( option )
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Apparent positive sequence impedance Zd
  • Apparent phase-to-phase impedances Z21, Z32, Z13
  • Phase displacement
  • Switchgear diagnosis type CT/VT supervision ANSI code: 60FL
  • Trip circuit supervision ANSI code: 74 ( option )
  • Auxiliary power supply monitoring
  • Nb of operations, operating time, charging time, nb of racking out operations ( option )
  • Cumulative breaking current
  • Complementary
  • Type of measurement Peak demand power
  • Energy
  • Power (P,Q)
  • Voltage
  • Frequency
  • Power factor
  • Current
  • Protection type Directional active underpower  ANSI code:  37P
  • Rate of change of frequency  ANSI code:  81R
  • Directional earth fault ANSI code: 67N/67NC
  • Directional phase overcurrent ANSI code: 67
  • Synchro-check ( option ) ANSI code: 25
  • Overvoltage (L-L or L-N) ANSI code: 59
  • Thermal overload for cables ANSI code: 49RMS
  • Earth fault/sensitive earth fault ANSI code: 50N/51N
  • Earth fault/sensitive earth fault ANSI code: 50G/51G
  • Negative sequence/unbalance ANSI code: 46
  • Remanent undervoltage ANSI code: 27R
  • Overfrequency ANSI code: 81H
  • Underfrequency ANSI code: 81L
  • Negative sequence overvoltage ANSI code: 47
  • Directional active overpower ANSI code: 32P
  • Positive sequence undercurrent ANSI code: 27D
  • Undervoltage (L-L or L-N) ANSI code: 27
  • Breaker failure ANSI code: 50BF
  • Neutral voltage displacement ANSI code: 59N
  • Phase overcurrent ANSI code: 50/51
  • Recloser (4 cycles) ( option ) ANSI code: 79
  • Communication port protocol Measurement readout ( option ) : Modbus
  • Remote control orders ( option ) : Modbus
  • Remote indication and time tagging of events ( option ) : Modbus
  • Remote protection setting ( option ) : Modbus
  • Transfer of disturbance recording data ( option ) : Modbus
  • Input output max capacity 42 inputs + 23 outputs
  • Communication compatibility Modbus RTU
  • DNP3
  • IEC 61850
  • IEC 60870-5-103
  • IEC 61850 goose message
  • Modbus TCPIP
  • User machine interface type Advanced
  • Remote
  • Without
  • Mimic-based
  • 2

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

11
    11
    Votre panier
    03534
    03534
    1 X 16.789,80DZD = 16.789,80DZD
    XDLPA14
    XDLPA14
    1 X 11.765,04DZD = 11.765,04DZD
    01106
    01106
    1 X 1.998,21DZD = 1.998,21DZD
    1502140000
    1502140000
    1 X 57.750,00DZD = 57.750,00DZD
    01104
    01104
    1 X 2.157,07DZD = 2.157,07DZD
    1502090000
    1502090000
    1 X 26.222,00DZD = 26.222,00DZD
    01221
    01221
    1 X 8.002,52DZD = 8.002,52DZD
    140DDI35300
    140DDI35300
    1 X 72.682,55DZD = 72.682,55DZD
    9001KP40G9
    9001KP40G9
    1 X 5.325,94DZD = 5.325,94DZD
    9001KP35LRR9
    9001KP35LRR9
    1 X 5.368,46DZD = 5.368,46DZD
    MIP30112T
    MIP30112T
    1 X 0,00DZD = 0,00DZD