Nos marques

Tous les produits Schneider

Produits récemment consultés

LC1F400FD

130.002,10DZD

LC1K09105B7

4.136,91DZD

KSA250DMBK4CF

299.395,33DZD

LC1D65AUD

27.547,02DZD

A9F73270

ACTI9 IC60N 2P 0,5A B DISJONCTEUR MINIAT

5.608,26DZD

UGS : 3d23aadbea02

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F73270 Marque : Schneider Disponibilité : En Stock



  • A9F73270
  • Characteristics
  • iC60N - miniature circuit breaker - 2P - 0.5A - B
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60N
  • Poles description 2P
  • Number of protected poles 2
  • [In] rated current 0.5 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 50 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 72...125 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 72...125 V DC
  • 50 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 6000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 6000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 25 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 25 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 4 x In +/- 20 %
  • [Ics] rated service breaking capacity 6000 A 100 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 10 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC
  • 10 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC
  • 6000 A 100 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 25 kA 100 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 25 kA 100 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    CA2KN22FC7
    CA2KN22FC7
    1 X 3.788,71DZD = 3.788,71DZD
    NSYMP1610
    NSYMP1610
    1 X 30.408,27DZD = 30.408,27DZD
    schneider
    CA2KN22S7
    1 X 4.197,29DZD = 4.197,29DZD
    LAD93217
    LAD93217
    1 X 21.045,27DZD = 21.045,27DZD
    schneider
    CA2KN22E72
    1 X 4.711,30DZD = 4.711,30DZD
    schneider
    CA2KN22L7
    1 X 3.900,14DZD = 3.900,14DZD
    schneider
    ZC4GM4
    2 X 12.574,63DZD = 25.149,26DZD
    TSXMFPP384K
    TSXMFPP384K
    1 X 101.006,60DZD = 101.006,60DZD
    LA9FH610
    LA9FH610
    1 X 22.766,13DZD = 22.766,13DZD