Nos marques

Tous les produits Schneider

Produits récemment consultés

GC2504B5

12.879,79DZD

LC1D123JD

9.342,34DZD

LC1DT40T7

14.839,46DZD

A9N21575

4.097,91DZD

A9F73601

ACTI9 IC60N 1P-N 1A B DISJONCTEUR MINIAT

5.806,07DZD

UGS : adb8d79df836

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

A9F73601 Marque : Schneider Disponibilité : En Stock



  • A9F73601
  • Characteristics
  • iC60N - miniature circuit breaker - 1P + N - 1A - B
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60N
  • Poles description 1P + N
  • Number of protected poles 1
  • Neutral position Left
  • [In] rated current 1 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 50 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 6000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 6000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 4 x In +/- 20 %
  • [Ics] rated service breaking capacity 6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • 2
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

15
    15
    Votre panier
    LE2D09Q7
    LE2D09Q7
    1 X 40.405,92DZD = 40.405,92DZD
    CA2KN22G7
    CA2KN22G7
    1 X 3.788,71DZD = 3.788,71DZD
    schneider
    CA2KN22L7
    2 X 3.900,14DZD = 7.800,28DZD
    16332
    16332
    1 X 165.171,38DZD = 165.171,38DZD
    LV431985
    LV431985
    1 X 202.512,31DZD = 202.512,31DZD
    LC1D123JD
    LC1D123JD
    1 X 9.342,34DZD = 9.342,34DZD
    18639
    18639
    1 X 23.945,56DZD = 23.945,56DZD
    VW3A4572
    VW3A4572
    1 X 206.059,85DZD = 206.059,85DZD
    XC1AC147
    XC1AC147
    1 X 27.669,33DZD = 27.669,33DZD
    schneider
    CA2KN22Z7
    1 X 3.788,71DZD = 3.788,71DZD
    ABE7E16EPN20
    ABE7E16EPN20
    1 X 12.895,95DZD = 12.895,95DZD
    ALB45254
    ALB45254
    1 X 3.907,13DZD = 3.907,13DZD
    schneider
    13508
    1 X 0,00DZD = 0,00DZD
    18637
    18637
    1 X 28.995,85DZD = 28.995,85DZD