Référence : A9F74220
Marque : Schneider
Disponibilité : En Stock
- A9F74220
- Characteristics
- miniature circuit breaker - iC60N - 2 poles - 20
- A - C curve
- Main
- Circuit breaker applica- Distribution
- tion
- Range of product IC60
- Device short name IC60N
- Poles description 2P
- Number of protected 2
- poles
- [In] rated current 20 A
- Network type AC
- DC
- Trip unit technology Thermal-magnetic
- Curve code C
- Utilisation category Category A conforming to EN 60947-2
- Category A conforming to IEC 60947-2
- Suitability for isolation Yes conforming to EN 60898-1
- Yes conforming to EN 60947-2
- Yes conforming to IEC 60898-1
- Yes conforming to IEC 60947-2
- Complementary
- Network frequency 50/60 Hz
- [Ue] rated operational voltage 100...130 V AC 50/60 Hz
- 12...60 V AC 50/60 Hz
- 220...240 V AC 50/60 Hz
- 380...415 V AC 50/60 Hz
- 400 V AC 50/60 Hz
- 440 V AC 50/60 Hz
- 12...144 V DC
- Magnetic tripping limit 8 x In +/- 20 %
- Breaking capacity 10 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
- 10 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
- 20 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
- 20 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
- 36 kA Icu conforming to EN 60947-2 - 100...130 V AC 50/60 Hz
- 36 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
- 36 kA Icu conforming to IEC 60947-2 - 100...130 V AC 50/60 Hz
- 36 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
- 6 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
- 6 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
- 6000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
- 6000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
- 6 kA Icu conforming to EN 60947-2 - 12...144 V DC
- 6 kA Icu conforming to IEC 60947-2 - 12...144 V DC
- [Ics] rated service breaking capacity 27 kA 75 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
- 27 kA 75 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
- 6 kA 100 % x Icu conforming to EN 60947-2 - 12...144 V DC
- 6 kA 100 % x Icu conforming to IEC 60947-2 - 12...144 V DC
- 27 kA 75 % x Icu conforming to EN 60947-2 - 100...130 V AC 50/60 Hz
- 15 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
- 7.5 kA 75 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
- 4.5 kA 75 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
- 27 kA 75 % x Icu conforming to IEC 60947-2 - 100...130 V AC 50/60 Hz
- 15 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
- 7.5 kA 75 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
- 4.5 kA 75 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
- Limitation class 3 conforming to EN 60898-1
- 3 conforming to IEC 60898-1
- [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
- 500 V AC 50/60 Hz conforming to IEC 60947-2
- Nov 26, 2012
- 1
- The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
- This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
- It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
- Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
- [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
- 6 kV conforming to IEC 60947-2
- Contact position indicator Yes
- Control type Toggle
- Local signalling Trip indicator
- Mounting mode Removable comb busbar installed
- Mounting support DIN rail
- 9 mm pitches 4
- Width 36 mm
- Colour White
- Connections - terminals Tunnel terminal with flap, top or bottom for 1...5 flexible wire(s) 1.5 mm² maxwith-
- out cable end
- Tunnel terminal with flap, top or bottom for 1...5 solid wire(s) 1.5 mm² max
- Tunnel terminal with flap, top or bottom for 1...3 flexible wire(s) 2.5 mm² maxwith-
- out cable end
- Tunnel terminal with flap, top or bottom for 1...3 solid wire(s) 2.5 mm² max
- Tunnel terminal with flap, top or bottom for 1 solid wire(s) 1...25 mm² max
- Tunnel terminal with flap, top or bottom for 1 flexible wire(s) 0.5...16 mm² maxwith
- cable end
- Tunnel terminal with flap, top or bottom for 1 flexible wire(s) 0.5...16 mm²
- maxwithout cable end
- Wire stripping length 14 mm top or bottom
- Tightening torque 2 N.m top or bottom
- Earth-leakage protection Separate block
- Environment
- Standards EN 60898-1
- EN 60947-2
- IEC 60898-1
- IEC 60947-2
- IP degree of protection IP3 conforming to EN 60947-2
- IP3 conforming to IEC 60947-2
- Pollution degree 3 conforming to EN 60947-2
- 3 conforming to IEC 60947-2
- Electrical shock protection class Class II front face
- Tropicalisation 2 conforming to EN/IEC 60068-2-78
- Relative humidity 95 %
- Operating altitude 0...2000 m
- Ambient air temperature for operation -35...70 °C
- Ambient air temperature for storage -40...85 °C
- RoHS EUR status Compliant
- RoHS EUR conformity date 1001