Nos marques

Tous les produits Schneider

Produits récemment consultés

KSB400DC4

237.556,25DZD

A9F73150

2.625,14DZD

MVS16N3MW6V

759.462,72DZD

A9C30811

2.007,41DZD

A9F74606

ACTI9 IC60N 1P-N 6A C DISJONCTEUR MINIAT

2.253,36DZD

UGS : 38ed1997f9f2

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F74606 Marque : Schneider Disponibilité : En Stock



  • A9F74606
  • Characteristics
  • iC60N - miniature circuit breaker - 1P + N - 6A - C
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60N
  • Poles description 1P + N
  • Number of protected poles 1
  • Neutral position Left
  • [In] rated current 6 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code C
  • Breaking capacity 20 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 20 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 6000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 10 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 36 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 36 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 6000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 8 x In +/- 20 %
  • [Ics] rated service breaking capacity 6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 27 kA 75 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 7.5 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 27 kA 75 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 7.5 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 15 kA 75 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 15 kA 75 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • 2
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

12
    12
    Votre panier
    ZBVB35
    ZBVB35
    1 X 1.485,95DZD = 1.485,95DZD
    A9F74606
    A9F74606
    1 X 2.253,36DZD = 2.253,36DZD
    MVS20N3NF6L
    MVS20N3NF6L
    1 X 586.306,44DZD = 586.306,44DZD
    LC1D09Z7
    LC1D09Z7
    1 X 8.802,41DZD = 8.802,41DZD
    MVS16N3MW6V
    MVS16N3MW6V
    1 X 759.462,72DZD = 759.462,72DZD
    NSYMR1210
    NSYMR1210
    1 X 27.803,63DZD = 27.803,63DZD
    XC1AC138
    XC1AC138
    1 X 42.886,88DZD = 42.886,88DZD
    XMLD035B1S11
    XMLD035B1S11
    1 X 43.637,55DZD = 43.637,55DZD
    18632
    18632
    1 X 16.945,35DZD = 16.945,35DZD
    MVS08H3MF6L
    MVS08H3MF6L
    1 X 540.148,31DZD = 540.148,31DZD
    16812
    16812
    1 X 6.649,93DZD = 6.649,93DZD
    ATS48C14Y
    ATS48C14Y
    1 X 341.179,74DZD = 341.179,74DZD