Nos marques

Tous les produits Schneider

Produits récemment consultés

A9C20631

3.714,50DZD

HMISCU6A5

142.940,90DZD

A9A15921

7.981,86DZD

A9F75163

ACTI9 IC60N 1P 63A D DISJONCTEUR MINIATU

2.936,52DZD

UGS : 8d76278479cc

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F75163 Marque : Schneider Disponibilité : En Stock



  • A9F75163
  • Characteristics
  • iC60N - miniature circuit breaker - 1P - 63A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60N
  • Poles description 1P
  • Number of protected poles 1
  • [In] rated current 63 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 20 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 20 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 72 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 72 V DC
  • 15 kA Icu conforming to EN 60947-2 - 12...60 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 12...60 V DC
  • 6000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 10 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 36 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 36 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 6000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 10 kA 100 % x Icu conforming to EN 60947-2 - 72 V DC
  • 10 kA 100 % x Icu conforming to IEC 60947-2 - 72 V DC
  • 6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V DC
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V DC
  • 6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 27 kA 75 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 7.5 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 27 kA 75 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 7.5 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 15 kA 75 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 15 kA 75 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 2
  • Height 85 mm
  • Width 18 mm
  • Depth 78.5 mm
  • Product weight 0.215 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...35 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...25 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 3.5 N.m top or bottom
  • Earth-leakage protection Without
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • 2
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    KSA400DMCK4CF
    KSA400DMCK4CF
    1 X 368.857,32DZD = 368.857,32DZD
    XB5AV65
    XB5AV65
    1 X 741,42DZD = 741,42DZD
    BLRCH075A090B40
    BLRCH075A090B40
    1 X 9.586,77DZD = 9.586,77DZD
    ZC4GM9
    ZC4GM9
    1 X 159.329,68DZD = 159.329,68DZD
    A9N19687
    A9N19687
    1 X 8.125,10DZD = 8.125,10DZD
    16332
    16332
    1 X 165.171,38DZD = 165.171,38DZD
    DF3FA20
    DF3FA20
    1 X 1.974,40DZD = 1.974,40DZD
    AR1MC013
    AR1MC013
    1 X 17,91DZD = 17,91DZD
    18608
    18608
    1 X 67.602,66DZD = 67.602,66DZD