Nos marques

Tous les produits Schneider

Produits récemment consultés

A9F95125

3.956,72DZD

VCCD01

7.284,04DZD

TM2DDO32UK

46.187,92DZD

A9F74104

1.620,55DZD

A9F75602

ACTI9 IC60N 1P-N 2A D DISJONCTEUR MINIAT

6.001,47DZD

UGS : 70cb399a62c6

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

A9F75602 Marque : Schneider Disponibilité : En Stock



  • A9F75602
  • Characteristics
  • iC60N - miniature circuit breaker - 1P + N - 2A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60N
  • Poles description 1P + N
  • Number of protected poles 1
  • Neutral position Left
  • [In] rated current 2 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 50 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 6000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 6000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • 2
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

18
    18
    Votre panier
    VLVAW3N03512AA
    VLVAW3N03512AA
    1 X 1.304.806,56DZD = 1.304.806,56DZD
    ABE7BV10
    ABE7BV10
    1 X 2.096,17DZD = 2.096,17DZD
    schneider
    CA2KN22S7
    1 X 4.197,29DZD = 4.197,29DZD
    A9F75602
    A9F75602
    1 X 6.001,47DZD = 6.001,47DZD
    A9F73663
    A9F73663
    1 X 7.523,04DZD = 7.523,04DZD
    MGU3.492.25
    MGU3.492.25
    1 X 636,19DZD = 636,19DZD
    XCKD2139P16
    XCKD2139P16
    1 X 7.023,31DZD = 7.023,31DZD
    15443
    15443
    1 X 10.123,76DZD = 10.123,76DZD
    schneider
    ZC4GM8
    1 X 149.050,35DZD = 149.050,35DZD
    LX1FL127
    LX1FL127
    1 X 38.742,32DZD = 38.742,32DZD
    10206
    10206
    1 X 446,43DZD = 446,43DZD
    KBA25ED4303W
    KBA25ED4303W
    1 X 13.503,32DZD = 13.503,32DZD
    18634
    18634
    1 X 16.945,35DZD = 16.945,35DZD
    A9F85403
    A9F85403
    1 X 15.435,73DZD = 15.435,73DZD
    KBB40ED2202TW
    KBB40ED2202TW
    1 X 16.052,88DZD = 16.052,88DZD
    ABE7BV20
    ABE7BV20
    1 X 2.776,00DZD = 2.776,00DZD
    12993
    12993
    1 X 1.147,21DZD = 1.147,21DZD
    18613
    18613
    1 X 10.041,72DZD = 10.041,72DZD