Nos marques

Tous les produits Schneider

Produits récemment consultés

UNYSPUEFUV1X

579.117,83DZD

140DDI35300

72.682,55DZD

ATV212WD45N4C

714.689,25DZD

UNYSPUSFUV1X

138.702,70DZD

A9F83102

ACTI9 IC60H 1P 2A B DISJONCTEUR MINIATUR

2.876,23DZD

UGS : 02853bca4a99

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F83102 Marque : Schneider Disponibilité : En Stock



  • A9F83102
  • Characteristics
  • iC60H - miniature circuit breaker - 1P - 2A - B
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 1P
  • Number of protected poles 1
  • [In] rated current 2 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 70 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 72 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 72 V DC
  • 20 kA Icu conforming to EN 60947-2 - 12...60 V DC
  • 20 kA Icu conforming to IEC 60947-2 - 12...60 V DC
  • 70 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 4 x In +/- 20 %
  • [Ics] rated service breaking capacity 15 kA 100 % x Icu conforming to EN 60947-2 - 72 V DC
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 72 V DC
  • 7500 A 75 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 20 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V DC
  • 20 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V DC
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 2
  • Height 85 mm
  • Width 18 mm
  • Depth 78.5 mm
  • Product weight 0.215 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Without
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    A9N21454
    A9N21454
    1 X 8.466,36DZD = 8.466,36DZD
    XCKM510H29
    XCKM510H29
    1 X 5.879,43DZD = 5.879,43DZD
    GC1622M5
    GC1622M5
    1 X 9.743,88DZD = 9.743,88DZD
    schneider
    9001KP40C9
    1 X 5.540,70DZD = 5.540,70DZD
    A9N61502
    A9N61502
    1 X 2.444,12DZD = 2.444,12DZD
    ABL1A02
    ABL1A02
    1 X 694,88DZD = 694,88DZD
    ATV212WD55N4
    ATV212WD55N4
    1 X 781.864,70DZD = 781.864,70DZD
    IMD-IM10
    IMD-IM10
    1 X 139.198,59DZD = 139.198,59DZD
    MGU3.511.25
    MGU3.511.25
    1 X 6.489,57DZD = 6.489,57DZD
    9001KP35LYA9
    9001KP35LYA9