Nos marques

Tous les produits Schneider

Produits récemment consultés

A9F75270

6.285,94DZD

LU9MR1C

2.785,74DZD

LX1FL415

38.742,32DZD

KBZ32APMR2

1.169,67DZD

A9F83206

ACTI9 IC60H 2P 6A B DISJONCTEUR MINIATUR

5.530,20DZD

UGS : 0f4a4c8d3ec5

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

A9F83206 Marque : Schneider Disponibilité : En Stock



  • A9F83206
  • Characteristics
  • iC60H - miniature circuit breaker - 2P - 6A - B
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 2P
  • Number of protected poles 2
  • [In] rated current 6 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 42 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 42 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 72...125 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 72...125 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 30 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 4 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC
  • 5 kA 50 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 5 kA 50 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

11
    11
    Votre panier
    ZB4BS62
    ZB4BS62
    1 X 2.860,53DZD = 2.860,53DZD
    MVS08H3MF2L
    MVS08H3MF2L
    1 X 515.596,11DZD = 515.596,11DZD
    GS1FD4
    GS1FD4
    1 X 32.886,63DZD = 32.886,63DZD
    EPH3500223
    EPH3500223
    1 X 1.236,83DZD = 1.236,83DZD
    ALB45254
    ALB45254
    1 X 3.907,13DZD = 3.907,13DZD
    ZC4GM9
    ZC4GM9
    1 X 159.329,68DZD = 159.329,68DZD
    LC1D95N7
    LC1D95N7
    1 X 28.305,35DZD = 28.305,35DZD
    schneider
    CA2KN22B72
    1 X 4.085,86DZD = 4.085,86DZD
    CA2KN22D7
    CA2KN22D7
    1 X 3.788,71DZD = 3.788,71DZD
    KBA25ABG4W
    KBA25ABG4W
    1 X 3.405,29DZD = 3.405,29DZD
    XACB681
    XACB681