Nos marques

Tous les produits Schneider

Produits récemment consultés

LX1D6W5

3.944,33DZD

LAD6K10U

9.165,79DZD

LE1D09Q7A05

13.852,46DZD

ATS48C14Y

341.179,74DZD

A9F84110

ACTI9 IC60H 1P 10A C DISJONCTEUR MINIATU

2.178,98DZD

UGS : 41a8acbc3f1b

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F84110 Marque : Schneider Disponibilité : En Stock



  • A9F84110
  • Characteristics
  • iC60H - miniature circuit breaker - 1P - 10A - C
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 1P
  • Number of protected poles 1
  • [In] rated current 10 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code C
  • Breaking capacity 30 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 72 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 72 V DC
  • 20 kA Icu conforming to EN 60947-2 - 12...60 V DC
  • 20 kA Icu conforming to IEC 60947-2 - 12...60 V DC
  • 10000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 42 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 42 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 8 x In +/- 20 %
  • [Ics] rated service breaking capacity 15 kA 100 % x Icu conforming to EN 60947-2 - 72 V DC
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 72 V DC
  • 7500 A 75 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 20 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V DC
  • 20 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V DC
  • 21 kA 50 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 2
  • Height 85 mm
  • Width 18 mm
  • Depth 78.5 mm
  • Product weight 0.215 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Without
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

11
    11
    Votre panier
    XS9D111A2L10
    XS9D111A2L10
    1 X 28.449,82DZD = 28.449,82DZD
    KNB16CF2
    KNB16CF2
    2 X 9.070,00DZD = 18.140,00DZD
    LV432813
    LV432813
    1 X 102.715,28DZD = 102.715,28DZD
    A9F73150
    A9F73150
    1 X 2.625,14DZD = 2.625,14DZD
    KSA1000EV4AF
    KSA1000EV4AF
    1 X 277.886,31DZD = 277.886,31DZD
    LR3D16
    LR3D16
    1 X 6.373,81DZD = 6.373,81DZD
    GC4030B5
    GC4030B5
    1 X 13.536,13DZD = 13.536,13DZD
    ZB4BW913
    ZB4BW913
    1 X 797,93DZD = 797,93DZD
    ABE7H16S21
    ABE7H16S21
    1 X 19.974,40DZD = 19.974,40DZD
    schneider
    CA3KN31ZD3
    1 X 5.736,09DZD = 5.736,09DZD