Nos marques

Tous les produits Schneider

Produits récemment consultés

GC4004M5

19.088,73DZD

A9F74603

2.673,93DZD

NSYSFTB18

118.848,09DZD

KBB25ED42305W

20.865,82DZD

A9F85204

ACTI9 IC60H 2P 4A D DISJONCTEUR MINIATUR

5.888,63DZD

UGS : 1d1b62ac2522

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F85204 Marque : Schneider Disponibilité : En Stock



  • A9F85204
  • Characteristics
  • iC60H - miniature circuit breaker - 2P - 4A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 2P
  • Number of protected poles 2
  • [In] rated current 4 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 70 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 72...125 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 72...125 V DC
  • 70 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 70 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

11
    11
    Votre panier
    TM221C24R
    TM221C24R
    1 X 53.879,77DZD = 53.879,77DZD
    LE1M35Q716
    LE1M35Q716
    1 X 14.446,81DZD = 14.446,81DZD
    XMPD12C2242
    XMPD12C2242
    1 X 10.848,23DZD = 10.848,23DZD
    KSA400ABDD4
    KSA400ABDD4
    1 X 271.306,50DZD = 271.306,50DZD
    XMLD035B1S11
    XMLD035B1S11
    1 X 43.637,55DZD = 43.637,55DZD
    BLRCH075A090B48
    BLRCH075A090B48
    1 X 9.358,27DZD = 9.358,27DZD
    schneider
    ZC4GM8
    1 X 149.050,35DZD = 149.050,35DZD
    BLRCS250A300B40
    BLRCS250A300B40
    1 X 14.390,23DZD = 14.390,23DZD
    A9C21642
    A9C21642
    1 X 8.759,38DZD = 8.759,38DZD
    A9F93420
    A9F93420
    1 X 11.625,94DZD = 11.625,94DZD
    KSA400DLF4B
    KSA400DLF4B
    1 X 212.848,51DZD = 212.848,51DZD