Nos marques

Tous les produits Schneider

Produits récemment consultés

BMH0703P11A2A

96.272,84DZD

LC1D40008U7

18.605,74DZD

MVS32N4NW2A

1.574.764,43DZD

K1C003NX

4.268,06DZD

A9F85216

ACTI9 IC60H 2P 16A D DISJONCTEUR MINIATU

5.608,24DZD

UGS : d24208c1897c

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F85216 Marque : Schneider Disponibilité : En Stock



  • A9F85216
  • Characteristics
  • iC60H - miniature circuit breaker - 2P - 16A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 2P
  • Number of protected poles 2
  • [In] rated current 16 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 42 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 42 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 72...125 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 72...125 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 30 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC
  • 5 kA 50 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 5 kA 50 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    ABE7H20E000
    ABE7H20E000
    2 X 8.196,49DZD = 16.392,98DZD
    schneider
    LC1DPK12V7
    1 X 29.702,00DZD = 29.702,00DZD
    ZB4BW0M134
    ZB4BW0M134
    2 X 2.843,77DZD = 5.687,54DZD
    schneider
    CA3KN31ND
    1 X 4.387,20DZD = 4.387,20DZD
    LP1K0910BD
    LP1K0910BD
    1 X 6.715,68DZD = 6.715,68DZD
    CA2KN22B7
    CA2KN22B7
    1 X 3.801,34DZD = 3.801,34DZD
    LC2D09J7
    LC2D09J7
    1 X 18.467,78DZD = 18.467,78DZD
    EPH3300123
    EPH3300123
    1 X 1.011,95DZD = 1.011,95DZD