Nos marques

Tous les produits Schneider

Produits récemment consultés

04031

4.164,00DZD

01130

22.549,63DZD

01109

1.316,14DZD

01106

1.998,21DZD

01104

2.157,07DZD

01094

5.767,92DZD

01034

27.660,32DZD

01033

28.293,02DZD

01210

1.268,55DZD

A9F85310

ACTI9 IC60H 3P 10A D DISJONCTEUR MINIATU

9.020,88DZD

UGS : 20fe75eda112

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F85310 Marque : Schneider Disponibilité : En Stock



  • A9F85310
  • Characteristics
  • iC60H - miniature circuit breaker - 3P - 10A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 3P
  • Number of protected poles 3
  • [In] rated current 10 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 42 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 42 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 125...180 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 125...180 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 30 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards IEC 60898-1
  • IEC 60947-2
  • EN 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • EN 60898-1
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 125...180 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 125...180 V DC
  • 5 kA 50 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 5 kA 50 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 6
  • Height 85 mm
  • Width 54 mm
  • Depth 78.5 mm
  • Product weight 0.375 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

2
    2
    Votre panier
    18635
    18635
    1 X 17.755,30DZD = 17.755,30DZD
    18609
    18609
    1 X 68.996,43DZD = 68.996,43DZD