Nos marques

Tous les produits Schneider

Produits récemment consultés

LC2D115V7

109.183,74DZD

LC1D40AG7

12.813,03DZD

XMPA06B2131

4.119,49DZD

LX1D8G7

8.498,77DZD

A9F85363

ACTI9 IC60H 3P 63A D DISJONCTEUR MINIATU

16.323,50DZD

UGS : c556ece81016

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F85363 Marque : Schneider Disponibilité : En Stock



  • A9F85363
  • Characteristics
  • iC60H - miniature circuit breaker - 3P - 63A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 3P
  • Number of protected poles 3
  • [In] rated current 63 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 42 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 42 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 125...180 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 125...180 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 30 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 125...180 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 125...180 V DC
  • 5 kA 50 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 5 kA 50 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 6
  • Height 85 mm
  • Width 54 mm
  • Depth 78.5 mm
  • Product weight 0.375 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...35 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...25 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 3.5 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

13
    13
    Votre panier
    LC2D09J7
    LC2D09J7
    1 X 18.467,78DZD = 18.467,78DZD
    XMPA06B2242
    XMPA06B2242
    1 X 4.516,97DZD = 4.516,97DZD
    MVS32N4NW2A
    MVS32N4NW2A
    2 X 1.574.764,43DZD = 3.149.528,86DZD
    EPH3300221
    EPH3300221
    1 X 1.011,95DZD = 1.011,95DZD
    MVS08H3MW6L
    MVS08H3MW6L
    1 X 740.774,83DZD = 740.774,83DZD
    A9F85216
    A9F85216
    3 X 5.608,24DZD = 16.824,72DZD
    LX1D8G7
    LX1D8G7
    1 X 8.498,77DZD = 8.498,77DZD
    DF2EA02
    DF2EA02
    1 X 660,33DZD = 660,33DZD
    A9F85316
    A9F85316
    1 X 8.591,34DZD = 8.591,34DZD
    schneider
    12597
    1 X 3.629,08DZD = 3.629,08DZD