  • A9F85403
  • Characteristics
  • iC60H - miniature circuit breaker - 4P - 3A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 4P
  • Number of protected poles 4
  • [In] rated current 3 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 70 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 180...250 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 180...250 V DC
  • 70 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 70 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 180...250 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 180...250 V DC
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 70 kA 100 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 8
  • Height 85 mm
  • Width 72 mm
  • Depth 78.5 mm
  • Product weight 0.5 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

14
    14
    Votre panier
    18609
    18609
    1 X 68.996,43DZD = 68.996,43DZD
    ASILUFC5
    ASILUFC5
    1 X 18.100,72DZD = 18.100,72DZD
    18638
    18638
    1 X 23.520,54DZD = 23.520,54DZD
    VDIP181546030
    VDIP181546030
    1 X 1.251,20DZD = 1.251,20DZD
    LC2K0601G72
    LC2K0601G72
    1 X 12.250,12DZD = 12.250,12DZD
    18635
    18635
    2 X 17.755,30DZD = 35.510,60DZD
    AB1GI
    AB1GI
    1 X 59,18DZD = 59,18DZD
    LP2K0910SD
    LP2K0910SD
    2 X 15.570,71DZD = 31.141,42DZD
    XC1AC131
    XC1AC131
    1 X 24.492,23DZD = 24.492,23DZD
    K1D004NX
    K1D004NX
    1 X 3.154,89DZD = 3.154,89DZD
    RSB2A080BD
    RSB2A080BD
    1 X 501,21DZD = 501,21DZD
    TSXDEZ32D2
    TSXDEZ32D2
    1 X 70.991,33DZD = 70.991,33DZD