Fiche technique du produit PDF : 

ACTI9 IC60L 4P 50A K DISJONCTEUR MINIATU

22.619,19DZD

UGS : 53018c400678

Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie : 

Produits associés
Référence :

A9F95450 Marque : Schneider Disponibilité : En Stock



  • A9F95450
  • Characteristics
  • iC60L - miniature circuit breaker - 4P - 50A - K
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60L
  • Poles description 4P
  • Number of protected poles 4
  • [In] rated current 50 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code K
  • Breaking capacity 70 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 70 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 20 kA Icu conforming to EN 60947-2 - 180...250 V DC
  • 20 kA Icu conforming to IEC 60947-2 - 180...250 V DC
  • 15000 A Icn conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
  • 10 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 30 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Standards IEC 60947-2
  • EN 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 35 kA 50 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 35 kA 50 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 20 kA 100 % x Icu conforming to EN 60947-2 - 180...250 V DC
  • 20 kA 100 % x Icu conforming to IEC 60947-2 - 180...250 V DC
  • 5 kA 50 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 5 kA 50 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 8
  • Height 85 mm
  • Width 72 mm
  • Depth 78.5 mm
  • Product weight 0.5 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...35 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...25 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 3.5 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • 2
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits qui pourraient aussi répondre à vos besoins

Produits récemment consultés

Aucun produit récemment consulté à afficher
références de produits

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

livraison rapide

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

expert senia electrique

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

Panier
0
    0
    Votre panier
    Votre panier est videRetourner à la boutique
    Retour en haut