ABR1E311M
UGS : bf6ea8a42676
Catégorie : Contrôle, Relais et Signalisation
INTERF R EM E10F 230V LED
10.047,83DZD
UGS :
bf6ea8a42676
Spécificités essentielles
Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie :
Catégorie :Contrôle, Relais et Signalisation
Produits associés
- Quick ViewAjouter au panier
ZENL1121
699,24DZD - Quick ViewAjouter au panier
ZENL1111
699,24DZD - Quick ViewAjouter au panier
ZD5PA203
2.646,07DZD
Produits liés à cet article
Référence : ABR1E311M
Marque : Schneider
Disponibilité : En Stock
- ABR1E311M
- Characteristics
- input interface module - 17.5 mm -
- electromechanical - 230/240 V AC - 1 C/O
- Main
- Range of product Interface for discrete signals
- Product or component type Electromechanical input interface module
- Contacts type and composition 1 C/O
- [Uc] control circuit voltage 230...240 V
- Control circuit type AC
- Control circuit frequency 50/60 Hz
- Width pitch dimension 17.5 mm
- [In] rated current <= 7 mA AC
- Reverse polarity protection With
- Short circuit protection 16 A external fuse gF (Ik <= 2.5 kA AC and Ik <= 100 A DC)
- 16 A external fuse gG (Ik <= 2.5 kA AC and Ik <= 100 A DC)
- [Ith] conventional free air thermal 2 A conforming to IEC 60947-1
- current
- Local signalling Green mechanical indicator for position of contacts and 1 green LED control signal state
- Complementary
- Control circuit voltage limits 264 V energization threshold: 170 V
- Housing colour Grey
- Connections - terminals Screw clamp terminal
- Drop-out voltage <= 68 V
- Holding current >= 2 mA AC
- Power dissipation in W <= 1.5 W
- Maximum switching voltage 125 V DC
- 252 V AC
- [Ue] rated operational voltage <= 125 V DC conforming to IEC 60947-5-1
- <= 230 V AC conforming to IEC 60947-5-1
- Network frequency 50/60 Hz
- [Ie] rated operational current 1 A AC-13 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
- 1 A AC-14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- 1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
- 1 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
- 2 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
- 2 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
- Minimum switching current 3 mA
- Minimum switching voltage 17 V
- Electrical reliability <= 0.00000001
- Operating time <= 12 ms between de-energisation of coil and closing of NC contact
- <= 12 ms between de-energisation of coil and closing of NO contact
- <= 12 ms between energisation of coil and closing of NC contact
- <= 12 ms between energisation of coil and closing of NO contact
- Contact bounce time <= 3 ms
- Operating rate in Hz <= 6 Hz at no-load
- <= 0.5 Hz at Ie
- Mechanical durability >= 10000000 cycles
- [Ui] rated insulation voltage 250 V conforming to IEC 60947-1
- 250 V conforming to VDE 0110 group C
- Flame retardance V0 conforming to UL 94
- Cable cross section 0.27...4 mm², 1 wire rigid
- 0.34...2.5 mm², 1 or 2 wires flexible with cable end
- 0.6...2.5 mm², 1 or 2 wires flexible without cable end
- 0.27...2.5 mm², 2 wires rigid
- Operating position Any position
- Installation category II conforming to IEC 60947-1
- Mounting support Asymmetrical DIN rail
- Combination rail
- Symmetrical DIN rail
- Product weight 0.095 kg
- Environment
- Immunity to microbreaks 5 ms
- Dielectric strength 1500 V between independent contacts
- 2500 V between wired interface and earth
- 4000 V between coil circuit and contact circuits
- Standards IEC 60947-5-1
- Product certifications LROS (Lloyds register of shipping)
- UL
- BV
- DNV
- CSA
- IP degree of protection IP20 conforming to IEC 60529
- Protective treatment TC
- Fire resistance 850 °C conforming to IEC 60695-2-1
- Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
- Vibration resistance 6 gn (f = 10...55 Hz) conforming to IEC 60068-2-6
- Electromagnetic compatibility 1.2/50 ms shock waves immunity test, 0.25 kV for U > 50 V conforming to IEC 255-4
- 1.2/50 ms shock waves immunity test, 0.5 kV for U < 50 V conforming to IEC 255-4
- Electrostatic discharge immunity test level 3, 8 kV conforming to IEC 61000-4-2
- Rapid transients immunity test, on input/output 1 kV conforming to IEC 61000-4-4
- Rapid transients immunity test, on power supply 2 kV conforming to IEC 61000-4-4
- Ambient air temperature for operation -20...60 °C at Un
- -5...40 °C unrestricted operation
- Ambient air temperature for storage -40...70 °C
- Operating altitude <= 3000 m
- Pollution degree 3 conforming to IEC 60947-5-1
- Contractual warranty
- Warranty period 18 months
- 2
- Product data sheet
- ABR1E311M
- Dimensions Drawings
- Electromechanical Interface Module
- Dimensions
- 3
- Product data sheet
- ABR1E311M
- Connections and Schema
- Electromechanical Interface Module
- Example of Application with PLC
- Interfacing PLC discrete inputs
- S1, S2 Pushbuttons series contacts
- (1) 2-wire sensors
- (2) PLC positive logic discrete inputs
- (3) 3-wire sensors
- 4
- Product data sheet
- ABR1E311M
- Connections and Schema
- Interface with Mechanical Indication + LED
- Circuit Diagram
- 1 C/O
- 5
Produits Similaires