Nos marques

Tous les produits Schneider

Produits récemment consultés

ZBVB35

1.485,95DZD

A9F74606

2.253,36DZD

A9F73110

1.466,75DZD

HMIZSUSBB

7.946,95DZD

ABR1S418B

UGS : ac732f066e26 Catégorie :
INTERF R EM S2F 24V LED

4.978,03DZD

UGS : ac732f066e26

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

ABR1S418B Marque : Schneider Disponibilité : En Stock



  • ABR1S418B
  • Characteristics
  • output interface module - 17.5 mm -
  • electromechanical - 24 V AC/DC - 2 NO
  • Main
  • Range of product Interface for discrete signals
  • Product or component type Electromechanical output interface module
  • Contacts type and composition 2 NO
  • [Uc] control circuit voltage 24 V
  • Control circuit type AC/DC
  • Control circuit frequency 50/60 Hz
  • Width pitch dimension 17.5 mm
  • [In] rated current <= 55 mA AC
  • <= 62 mA DC
  • Reverse polarity protection With, circuit application: yes
  • Short circuit protection 16 A external fuse gF (Ik <= 2.5 kA AC and Ik <= 100 A DC)
  • 16 A external fuse gG (Ik <= 2.5 kA AC and Ik <= 100 A DC)
  • [Ith] conventional free air thermal 12 A conforming to IEC 60947-1
  • current
  • Local signalling Green mechanical indicator for position of contacts and 1 green LED control signal state
  • Complementary
  • Control circuit voltage limits 30 V energization threshold: 16.5 V
  • Maximum switching voltage 125 V DC
  • Housing colour Grey
  • Connections - terminals Screw clamp terminal
  • Drop-out voltage <= 3.8 V
  • Holding current >= 4.9 mA DC
  • >= 5.2 mA AC
  • Power dissipation in W <= 1.5 W
  • [Ue] rated operational voltage <= 125 V DC conforming to IEC 60947-5-1
  • <= 230 V AC conforming to IEC 60947-5-1
  • Network frequency 50/60 Hz
  • [Ie] rated operational current 1 A AC-13 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • 1 A AC-14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 1 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
  • 4 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 5 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
  • Minimum switching current 3 mA
  • Minimum switching voltage 17 V
  • Electrical reliability <= 0.00000001
  • Operating time <= 12 ms between de-energisation of coil and closing of NC contact
  • <= 12 ms between de-energisation of coil and closing of NO contact
  • <= 12 ms between energisation of coil and closing of NC contact
  • <= 12 ms between energisation of coil and closing of NO contact
  • Contact bounce time <= 3 ms
  • Operating rate in Hz <= 6 Hz at no-load
  • <= 0.5 Hz at Ie
  • Mechanical durability >= 20000000 cycles
  • [Ui] rated insulation voltage 250 V conforming to IEC 60947-1
  • 250 V conforming to VDE 0110 group C
  • Flame retardance V0 conforming to UL 94
  • Cable cross section 0.27...4 mm², 1 wire rigid
  • 0.34...2.5 mm², 1 or 2 wires flexible with cable end
  • 0.6...2.5 mm², 1 or 2 wires flexible without cable end
  • 0.27...2.5 mm², 2 wires rigid
  • Operating position Any position
  • Installation category II conforming to IEC 60947-1
  • Mounting support Asymmetrical DIN rail
  • Combination rail
  • Symmetrical DIN rail
  • Product weight 0.095 kg
  • Environment
  • Immunity to microbreaks 8 ms
  • Dielectric strength 1500 V for 1 minute between independent contacts
  • 2500 V for 1 minute between wired interface and earth
  • 4000 V for 1 minute between coil circuit and contact circuits
  • Standards IEC 60947-5-1
  • Product certifications BV
  • CSA
  • DNV
  • LROS (Lloyds register of shipping)
  • UL
  • IP degree of protection IP20 conforming to IEC 60529
  • Protective treatment TC
  • Fire resistance 850 °C conforming to IEC 60695-2-1
  • Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
  • Vibration resistance 6 gn (f = 10...55 Hz) conforming to IEC 60068-2-6
  • Electromagnetic compatibility 1.2/50 ms shock waves immunity test, 0.25 kV for U > 50 V conforming to IEC 255-4
  • 1.2/50 ms shock waves immunity test, 0.5 kV for U < 50 V conforming to IEC 255-4
  • Electrostatic discharge immunity test level 3, 8 kV conforming to IEC 61000-4-2
  • Rapid transients immunity test, on input/output 1 kV conforming to IEC 61000-4-4
  • Rapid transients immunity test, on power supply 2 kV conforming to IEC 61000-4-4
  • Ambient air temperature for operation -20...60 °C at Un
  • -5...40 °C unrestricted operation
  • Ambient air temperature for storage -40...70 °C
  • Operating altitude <= 3000 m
  • Pollution degree 3 conforming to IEC 60947-5-1
  • Contractual warranty
  • Warranty period 18 months
  • 2
  • Product data sheet
  • ABR1S418B
  • Dimensions Drawings
  • Electromechanical Interface Module
  • Dimensions
  • 3
  • Product data sheet
  • ABR1S418B
  • Connections and Schema
  • Electromechanical Interface Module
  • Example of Application with PLC
  • Interfacing PLC discrete outputs
  • (1) Essential on inductive loads (can be replaced with peak limiter)
  • (2) PLC positive logic transistor (or relay) outputs
  • 4
  • Product data sheet
  • ABR1S418B
  • Connections and Schema
  • Interface with Mechanical Indication + LED
  • Circuit Diagram
  • 2 N/O
  • 5
  • Product data sheet
  • ABR1S418B
  • Performance Curves
  • Electrical Durability of Contacts
  • AC Loads
  • Test conditions: in accordance with standard IEC 947-5-1 set up for rated control voltage, operating rate: 1800 cycles/hour. (0.5 Hz).
  • AC-12 operating cycles in millions
  • AC-12 Control of resistive loads and isolated solid state loads via optocoupler (cos ϕ ≥ 0.9)
  • (1) 24 V
  • (2) 48 V
  • (3) 127 V
  • (4) 230 V
  • AC-13 operating cycles in millions
  • AC-13 Control of isolated solid state loads via transformer (cos ϕ ≥ 0.65)
  • (1) 24 V
  • (2) 48 V
  • (3) 127 V
  • (4) 230 V
  • 6
  • AC-14 and AC-15 operating cycles in millions
  • AC-14 Control of weak electromagnetic loads of electromagnets ≤ 72 VA (make: cos ϕ = 0.3, break: cos ϕ = 0.3)
  • AC-15 Control of electromagnetic loads of electromagnets > 72 VA (make: cos ϕ = 0.7, break: cos ϕ =0.4)
  • (1) 24 V
  • (2) 48 V
  • (3) 127 V
  • (4) 230 V
  • DC Loads
  • Test conditions: in accordance with standard IEC 947-5-1 set up for rated control voltage, operating rate: 1800 cycles/hour. (0.5 Hz).
  • DC-12 operating cycles in millions
  • DC-12 Control of resistive loads and isolated solid state loads via optocoupler (L/R ≤ 1 ms)
  • (1) 24 V
  • (2) 48 V
  • (3) 127 V
  • DC-13 operating cycles in millions
  • DC-13 Control of electromagnets (L/R ≤ 2 x (Ue x Ie) in ms, with Ue: rated operating voltage and Ie: rated operating current)
  • (1) 24 V
  • (2) 48 V
  • (3) 127 V
  • 7

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

12
    12
    Votre panier
    KSB400DC4
    KSB400DC4
    1 X 237.556,25DZD = 237.556,25DZD
    16012
    16012
    1 X 535,51DZD = 535,51DZD
    ZB4BW0G154
    ZB4BW0G154
    1 X 4.465,29DZD = 4.465,29DZD
    MVS08N3MW6A
    MVS08N3MW6A
    1 X 725.442,73DZD = 725.442,73DZD
    ZCY44
    ZCY44
    1 X 2.074,90DZD = 2.074,90DZD
    BLRCH075A090B48
    BLRCH075A090B48
    1 X 9.358,27DZD = 9.358,27DZD
    ZENL1111
    ZENL1111
    1 X 699,24DZD = 699,24DZD
    RUMC32BD
    RUMC32BD
    1 X 2.324,95DZD = 2.324,95DZD
    ATS48C32Y
    ATS48C32Y
    1 X 538.905,25DZD = 538.905,25DZD
    HMIS85
    HMIS85
    1 X 44.240,21DZD = 44.240,21DZD
    ATV630C16N4F
    ATV630C16N4F
    1 X 3.352.071,09DZD = 3.352.071,09DZD
    9001KP35LRR31
    9001KP35LRR31
    1 X 7.706,11DZD = 7.706,11DZD