ABR2E111M
UGS : 22072611ea92
Catégorie : Contrôle, Relais et Signalisation
INTERF R EM E9MM230 240CA
9.485,93DZD
UGS :
22072611ea92
Spécificités essentielles
Produits associés
-
Quick ViewAjouter au panier
-
Quick ViewAjouter au panier
-
Quick ViewAjouter au panier
Options et accessoires compatibles
Référence : ABR2E111M
Marque : Schneider
Disponibilité : En Stock
- ABR2E111M
- Characteristics
- input interface module - 9.5 mm -
- electromechanical - 230/240 V AC - 1 NC
- Main
- Range of product Interface for discrete signals
- Product or component type Slim electromechanical input interface module
- Contacts type and composition 1 NO
- [Uc] control circuit voltage 230...240 V
- Control circuit type AC
- Control circuit frequency 50/60 Hz
- Width pitch dimension 9.5 mm
- [In] rated current <= 0.015 A
- Short circuit protection 2 A external fuse fast blow
- [Ith] conventional free air thermal 1 A conforming to IEC 60947-1
- current
- Local signalling 1 LED indicating control signal state
- Quantity per set Set of 5
- Complementary
- Control circuit voltage limits 264 V
- Connections - terminals Screw clamp terminal
- Operating threshold 186 V
- Drop-out voltage <= 48 V
- Holding current 2.5 mA
- Power dissipation in W 0.54 W 50 Hz
- 0.77 W 60 Hz
- Maximum switching voltage 125 V DC
- 140 V AC
- [Ue] rated operational voltage <= 100 V DC conforming to IEC 60947-5-1 for built-in contacts
- <= 127 V AC conforming to IEC 60947-5-1 for built-in contacts
- Network frequency 50/60 Hz
- [Ie] rated operational current 1 A AC-12 Ue: 127 V per 1000000 cycles conforming to IEC 60947-5-1
- 1 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- 1 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
- 0.5 A AC-14 Ue: 127 V per 1000000 cycles conforming to IEC 60947-5-1
- 0.5 A AC-15 Ue: 127 V per 1000000 cycles conforming to IEC 60947-5-1
- Minimum switching current 1 mA
- Minimum switching voltage 5 V
- Electrical reliability 1e-008
- Operating time <= 30 ms between de-energisation of coil and closing of NO contact AC
- <= 30 ms between energisation of coil and closing of NO contact AC
- Contact bounce time <= 5 ms
- Operating rate in Hz 10 Hz at no-load
- 0.5 Hz at Ie
- Mechanical durability >= 20000000 cycles
- [Ui] rated insulation voltage 250 V conforming to VDE 0110 group C
- 300 V conforming to IEC 60947-1
- Flame retardance V0 conforming to UL 94
- Cable cross section 0.27...4 mm², 1 wire rigid
- 0.34...2.5 mm², 1 or 2 wires flexible with cable end
- 0.6...2.5 mm², 1 or 2 wires flexible without cable end
- Operating position Any position
- Installation category II conforming to IEC 60947-1
- Mounting support Asymmetrical DIN rail
- Combination rail
- Symmetrical DIN rail
- Product weight 0.036 kg
- Environment
- Immunity to microbreaks 10 ms
- Dielectric strength 2000 V between coil circuit and contact circuits
- 2500 V between wired interface and earth
- 750 V between open contacts
- Standards IEC 60947-5-1
- Product certifications BV
- CSA
- DNV
- LROS (Lloyds register of shipping)
- UL
- IP degree of protection IP20 conforming to IEC 60529
- Protective treatment TC
- Fire resistance 960 °C conforming to IEC 60695-2-1
- Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
- Vibration resistance 3 gn (f = 10...150 Hz) conforming to IEC 60068-2-6
- Electromagnetic compatibility 1.2/50 µs shock waves immunity test, 0.5 kV for U < 50 V conforming to IEC 947-1
- 1.2/50 µs shock waves immunity test, 1.5 kV for U < 150 V conforming to IEC 947-1
- 1.2/50 µs shock waves immunity test, 2.5 kV for U < 300 V conforming to IEC 947-1
- Electromagnetic field immunity test level 3, 10 V/m between 27...1000 MHz conforming to IEC
- 61000-4-3
- Electrostatic discharge immunity test level 3, 8 kV conforming to IEC 61000-4-2
- Rapid transients immunity test level 3, on input/output 1 kV conforming to IEC 61000-4-4
- Rapid transients immunity test level 3, on power supply 2 kV conforming to IEC 61000-4-4
- Ambient air temperature for operation -5...40 °C unrestricted operation
- -25...70 °C at Us
- -5...55 °C from 0.85...1.1 Us
- Ambient air temperature for storage -40...80 °C
- Operating altitude <= 3000 m
- Pollution degree 2 conforming to IEC 60947-1
- Contractual warranty
- Warranty period 18 months
- 2
- Product data sheet
- ABR2E111M
- Dimensions Drawings
- Slim Electromechanical Interface Module
- Dimensions
- 3
- Product data sheet
- ABR2E111M
- Connections and Schema
- Slim Electromechanical Interface Module
- Example of Application with PLC
- Interfacing PLC discrete inputs
- S1 Pushbuttons series contacts
- (1) Processing power supply
- (2) PLC positive logic discrete inputs
- (3) Process power supply
- (4) 2-wire sensors
- (5) 3-wire sensors
- 4
- Product data sheet
- ABR2E111M
- Connections and Schema
- Slim Electromechanical Interface Module
- Circuit Diagram
- 1 N/O
- 5