Référence : ABT7PDU250B
Marque : Schneider
Disponibilité : En Stock
- ABT7PDU250B
- Characteristics
- voltage transformer - 230..400 V - 2 x 24 V - 2.5
- KVA
- Main
- Range of product Phaseo Universal
- Product or component type Safety and isolation transformer
- Rated power in VA 2500 VA
- Input voltage 230 V AC single phase, terminal(s): N-L1
- 400 V AC phase to phase, terminal(s): L1-L2
- Output voltage 24/48 V AC
- Secondary winding Double
- Protective cover Without
- Ambient air temperature for -20...60 °C
- operation
- Complementary
- Input voltage limits 207...253 V
- 360...440 V
- Network frequency limits 47...63 Hz
- Input voltage tolerance +/- 15 V
- Efficiency 96 %
- Power dissipation in W 104.2 W
- Voltage variation at nominal load 0,0145 at 230 V
- 0,0212 at 400 V
- Output sustained overvoltage 0,005 (no load, hot state)
- Voltage drop at rated load 2.29 %
- No load losses 40.5 W
- Short-circuit voltage 0,028
- Output protection type Against overload, protection technology: external
- Against overvoltage, protection technology: external
- Against short-circuits, protection technology: external
- Connections - terminals Screw type terminals for input connection, connection capacity: 5 x 4 mm² AWG 11
- Screw type terminals for input ground connection, connection capacity: 1 x 4 mm²
- AWG 11
- Screw type terminals for output connection, connection capacity: 4 x 35 mm² AWG 2
- Marking CE
- Fixing mode By 4 screws, screw(s) Ø = 10 mm on horizontal panel with derating to 90 %
- By 4 screws, screw(s) Ø = 10 mm on vertical panel, operating position: horizontal
- By 4 screws, screw(s) Ø = 10 mm on vertical panel, operating position: horizontal
- By 4 screws, screw(s) Ø = 10 mm on vertical panel, operating position: vertical
- Output coupling Grounding of secondary
- Parallel
- Series by internal jumper
- Operating altitude 3000 m
- Electrical insulation class Class F
- Product weight 28 kg
- Environment
- product certifications UR
- EAC
- standards UL 506
- IP degree of protection IP20
- environmental characteristic EMC conforming to EN 62041
- Safety conforming to EN 61558-1
- Safety conforming to EN 61558-2-6
- ambient air temperature for storage -40...80 °C
- 1 / 3
- The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
- This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
- It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
- Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
- relative humidity 0...95 % during operation
- overvoltage category Class I conforming to VDE 0106-1
- dielectric strength 3200 V between input and ground
- 3200 V between output and ground
- 5100 V between input and output
- Dimensions
- Dimensions in mm
- a b c G J Ø
- 192 178 180 150 150 10
- Dimensions in in.
- a b c G J Ø
- 7.56 7.01 7.09 5.90 5.90 0.39
- Internal Scheme
- Primary Voltage Wiring
- Secondary Voltage Wiring
- 2 / 3