  • Characteristics
  • TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V
  • 32 A - 480 V AC 50/60 Hz coil
  • Main
  • Range of product TeSys D
  • Range TeSys
  • Product name TeSys D
  • Product or component type Contactor
  • Device short name LC1D
  • Contactor application Resistive load
  • Utilisation category AC-1
  • Poles description 4P
  • Pole contact composition 4 NO
  • [Ue] rated operational voltage <= 300 V DC for power circuit
  • <= 690 V AC 25...400 Hz for power circuit
  • [Ie] rated operational current 32 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
  • Control circuit type AC 50/60 Hz
  • Control circuit voltage 480 V AC 50/60 Hz
  • Auxiliary contact composition 1 NO + 1 NC
  • [Uimp] rated impulse withstand voltage Conforming to IEC 60947
  • Overvoltage category III
  • [Ith] conventional free air thermal 32 A at <= 60 °C for power circuit
  • current 10 A at <= 60 °C for signalling circuit
  • Irms rated making capacity 300 A at 440 V for power circuit conforming to IEC 60947
  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current 145 A <= 40 °C 10 s power circuit
  • 240 A <= 40 °C 1 s power circuit
  • 40 A <= 40 °C 10 min power circuit
  • 84 A <= 40 °C 1 min power circuit
  • 100 A 1 s signalling circuit
  • 120 A 500 ms signalling circuit
  • 140 A 100 ms signalling circuit
  • Associated fuse rating 35 A gG at <= 690 V coordination type 2 for power circuit
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • 50 A gG at <= 690 V coordination type 1 for power circuit
  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • Average impedance 2.5 mOhm at 50 Hz - Ith 32 A for power circuit
  • [Ui] rated insulation voltage 600 V for power circuit certifications CSA
  • 600 V for power circuit certifications UL
  • 690 V for power circuit conforming to IEC 60947-4-1
  • 690 V for signalling circuit conforming to IEC 60947-1
  • 600 V for signalling circuit certifications CSA
  • 600 V for signalling circuit certifications UL
  • Electrical durability 1 Mcycles 32 A AC-1 at Ue <= 440 V
  • Power dissipation per pole 2.5 W AC-1
  • Protective cover With
  • Mounting support Plate
  • Rail
  • Standards CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
  • Product certifications BV
  • GOST
  • RINA
  • UL
  • CCC
  • LROS
  • GL
  • DNV
  • CSA
  • Connections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
  • end
  • Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
  • end
  • Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
  • end
  • Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
  • Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
  • Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
  • Power circuit : connector 1 cable(s) 2.5...10 mm² - cable stiffness: flexible - without cable end
  • Power circuit : connector 2 cable(s) 2.5...10 mm² - cable stiffness: flexible - without cable end
  • Power circuit : connector 1 cable(s) 2.5...10 mm² - cable stiffness: flexible - with cable end
  • Power circuit : connector 2 cable(s) 2.5...10 mm² - cable stiffness: flexible - with cable end
  • Power circuit : connector 1 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable end
  • Power circuit : connector 2 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable end
  • Tightening torque Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • Power circuit : 1.7 N.m - on connector - with screwdriver flat Ø 6 mm
  • Power circuit : 1.7 N.m - on connector - with screwdriver Philips No 2
  • Operating time 4...19 ms opening
  • 12...22 ms closing
  • Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Mechanical durability 15 Mcycles
  • Operating rate 3600 cyc/h at <= 60 °C
  • Complementary
  • Coil technology Without built-in suppressor module
  • Control circuit voltage limits 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz
  • 0.8...1.1 Uc operational at 60 °C, AC 50 Hz
  • 0.85...1.1 Uc operational at 60 °C, AC 60 Hz
  • Inrush power in VA 70 VA at 20 °C (cos ϕ 0.75) 60 Hz
  • 70 VA at 20 °C (cos ϕ 0.75) 50 Hz
  • Hold-in power consumption in VA 7.5 VA at 20 °C (cos ϕ 0.3) 60 Hz
  • 7 VA at 20 °C (cos ϕ 0.3) 50 Hz
  • Heat dissipation 2...3 W at 50/60 Hz
  • Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
  • 2
  • Type mirror contact (1 NC) conforming to IEC 60947-4-1
  • Signalling circuit frequency 25...400 Hz
  • Minimum switching current 5 mA for signalling circuit
  • Minimum switching voltage 17 V for signalling circuit
  • Non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
  • 1.5 ms on energisation (between NC and NO contact)
  • Insulation resistance > 10 MOhm for signalling circuit
  • Environment
  • IP degree of protection IP2x front face conforming to IEC 60529
  • Protective treatment TH conforming to IEC 60068-2-30
  • Pollution degree 3
  • Ambient air temperature for operation -5...60 °C
  • Ambient air temperature for storage -60...80 °C
  • Permissible ambient air temperature -40...70 °C at Uc
  • around the device
  • Operating altitude 3000 m without derating in temperature
  • Fire resistance 850 °C conforming to IEC 60695-2-1
  • Flame retardance V1 conforming to UL 94
  • Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
  • Vibrations contactor closed 4 Gn, 5...300 Hz
  • Shocks contactor closed 15 Gn for 11 ms
  • Shocks contactor open 8 Gn for 11 ms
  • Height 91 mm
  • Width 45 mm
  • Depth 99 mm
  • Product weight 0.425 kg
  • Offer Sustainability
  • Sustainable offer status Not Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  0709  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • Product end of life instructions Need no specific recycling operations
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

Produits récemment consultés

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    CA2KN22V7
    CA2KN22V7
    1 X 4.085,86DZD = 4.085,86DZD
    01094
    01094
    1 X 5.767,92DZD = 5.767,92DZD
    schneider
    CA2KN22L7
    1 X 3.900,14DZD = 3.900,14DZD
    schneider
    CA2KN22FE72
    1 X 4.406,32DZD = 4.406,32DZD
    CA2KN22P7
    CA2KN22P7
    1 X 3.801,34DZD = 3.801,34DZD
    CA2KN22N7
    CA2KN22N7
    1 X 4.085,86DZD = 4.085,86DZD
    04031
    04031
    1 X 4.164,00DZD = 4.164,00DZD
    CA2KN22U7
    CA2KN22U7
    1 X 3.788,71DZD = 3.788,71DZD
    schneider
    CA2KN22J7
    1 X 3.788,71DZD = 3.788,71DZD
    01109
    01109
    1 X 1.316,14DZD = 1.316,14DZD