LC1E0910F5
3P CONTACTOR EasyPact TVS 1NO 4KW 400V
1.758,95DZD
UGS :
e9bfd0c7262d
Spécificités essentielles
Produits associés
-
Quick ViewAjouter au panier
-
Quick ViewAjouter au panier
-
Quick ViewAjouter au panier
Options et accessoires compatibles
Référence : LC1E0910F5
Marque : Schneider
Disponibilité : En Stock
- LC1E0910F5
- Characteristics
- EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440
- V 9A - 110 V AC coil
- Main
- Range EasyPact
- Product name EasyPact TVS
- Product or component type Contactor
- Device short name LC1E
- Contactor application Motor control
- Resistive load
- Utilisation category AC-1
- AC-3
- Poles description 3P
- Pole contact composition 3 NO
- [Ue] rated operational voltage <= 690 V AC 50/60 Hz for power circuit
- [Ie] rated operational current 9 A (<= 60 °C) AC AC-3 for power circuit <= 440 V
- 25 A (<= 60 °C) AC AC-1 for power circuit <= 440 V
- Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz
- 4 kW at 380...400 V
- 4 kW at 440 V
- 5.5 kW at 500 V
- 4 kW at 415 V
- 5.5 kW at 660...690 V
- Control circuit type AC 50 Hz
- Control circuit voltage 110 V AC 50 Hz
- Auxiliary contact composition 1 NO
- [Uimp] rated impulse withstand voltage 6 kV (coil not connected to the power circuit) IEC 60947
- Overvoltage category III
- Irms rated making capacity 90 A - 440 V AC for power circuit conforming to IEC 60947-4-1
- Rated breaking capacity 72 kA at 440 V for power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current 105 kA at <= 40 °C - 10 s for power circuit
- 61 kA at <= 40 °C - 60 s for power circuit
- 30 kA at <= 40 °C - 600 s for power circuit
- Associated fuse rating 20 A gG <= 690 V type 1 power circuit
- 10 A gG <= 690 V type 1 control circuit IEC 60947-5-1
- Average impedance 2.5 mOhm at 50 Hz Ith 25 A for power circuit
- [Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
- Electrical durability 1400000 cycles AC-3
- 150000 cycles AC-1
- Power dissipation per pole 0.2 W AC-3
- 1.6 W AC-1
- Mounting support DIN rail
- Plate
- Standards IEC 60947-1
- IEC 60947-4-1
- IEC 60947-5-1
- Product certifications GOST
- Connections - terminals Power circuit : screw clamp terminals - 1 flexible cable(s) 1...4 mm² with cable end
- cable end
- Power circuit : screw clamp terminals - 2 flexible cable(s) 1...2.5 mm² with cable end
- cable end
- Power circuit : screw clamp terminals - 1 solid cable(s) 1...4 mm² without cable end
- cable end
- Power circuit : screw clamp terminals - 2 solid cable(s) 1...4 mm² without cable end
- cable end
- Control circuit : screw clamp terminals - 1 flexible cable(s) 1...4 mm² without cable
- end cable end
- Control circuit : screw clamp terminals - 2 flexible cable(s) 1...4 mm² without cable
- 1 / 2
- The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
- This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
- It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
- Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
- end cable end
- Control circuit : screw clamp terminals - 1 flexible cable(s) 1...4 mm² with cable end
- cable end
- Control circuit : screw clamp terminals - 2 flexible cable(s) 1...2.5 mm² with cable end
- cable end
- Control circuit : screw clamp terminals - 1 solid cable(s) 1...4 mm² without cable end
- cable end
- Control circuit : screw clamp terminals - 2 solid cable(s) 1...4 mm² without cable end
- cable end
- Tightening torque 1.2 N.m for power circuit
- 1.5 N.m for control circuit
- Operating time 12...22 ms on closing
- 4...19 ms on opening
- Mechanical durability 10000000 cycles
- Operating rate 1800 cyc/h at <= 60 °C
- Complementary
- Control circuit voltage limits 0.85...1.1 Uc at <= 55 °C operational 50 Hz
- 0.3...0.6 Uc at <= 55 °C drop-out 50 Hz Inrush power in VA 95 VA at 20 °C (0.75) 60 Hz 95 VA at 20 °C (0.75) 50 Hz Hold-in power consumption in VA 8.5 VA at 20 °C (0.3) 50 Hz 8.5 VA at 20 °C (0.3) 60 Hz Heat dissipation 2...3 W for control circuit Minimum switching current 5 mA control circuit Minimum switching voltage 17 V control circuit Non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact Insulation resistance > 10 MOhm control circuit
- Environment
- IP degree of protection IP2x conforming to IEC 60529
- protective treatment TH IEC 60068 3
- pollution degree 3
- ambient air temperature for operation 5...55 °C
- ambient air temperature for storage -60...80 °C
- permissible ambient air temperature around the device -20...70 °C at Uc
- operating altitude 3000 m without derating
- fire resistance 850 °C IEC 60695-2-1
- mechanical robustness Vibrations contactor closed 3 Gn, 5...300 Hz
- Shocks contactor closed 10 Gn for 11 ms
- Shocks contactor open 7 Gn for 11 ms
- Vibrations contactor open 1.5 Gn, 5...300 Hz
- height 74 mm
- width 45 mm
- depth 80 mm
- product weight 0.3 kg
- Offer Sustainability
- Sustainable offer status Green Premium product
- RoHS (date code: YYWW) Compliant - since 1110 - Schneider Electric declaration of conformity
- REACh Reference not containing SVHC above the threshold
- Product environmental profile Available
- Product end of life instructions Need no specific recycling operations
- Contractual warranty
- Warranty period 18 months
- 2 / 2
Produits Similaires
Produits similaires
Produits récemment consultés