LC3D09AE7
S.D 1S ON PLATE 48V50/60 STAR DELTA
43.614,50DZD
UGS :
f92ee8a2d954
Spécificités essentielles
Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie :
Produits associés
- Quick ViewAjouter au panier
ZC4GM9
159.329,68DZD - Quick ViewAjouter au panier
ZC4GM8
149.050,35DZD - Quick ViewAjouter au panier
ZC4GM4
12.574,63DZD
Produits liés à cet article
Référence : LC3D09AE7
Marque : Schneider
Disponibilité : En Stock
- LC3D09AE7
- Characteristics
- TeSys D - star delta starter - 3 x 3P (3 NO) - 9 A -
- 48 V AC coil
- Main
- Range TeSys
- Product name TeSys D
- Product or component type Star delta starter
- Device short name LC3D
- Contactor application Motor control
- Utilisation category AC-3
- Device presentation Pre-wired
- Poles description 3 x 3P
- Pole contact composition 3 x 3 NO
- [Ue] rated operational voltage <= 690 V AC 25...400 Hz for power circuit
- [Ie] rated operational current 9 A (<= 60 °C) AC AC-3 for power circuit at <= 440 V
- Motor power kW 4 kW at 220/230 V AC 50/60 Hz
- 7.5 kW at 380/400 V AC 50/60 Hz
- 7.5 kW at 415 V AC 50/60 Hz
- 7.5 kW at 440 V AC 50/60 Hz
- Control circuit type AC 50/60 Hz
- Control circuit voltage 48 V AC 50/60 Hz
- Auxiliary contact composition 1 NC for KM1 star contactor
- [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
- Overvoltage category III
- [Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1 power circuit
- 600 V certifications CSA power circuit
- 600 V certifications UL power circuit
- 690 V conforming to IEC 60947-1 signalling circuit
- 600 V certifications CSA signalling circuit
- 600 V certifications UL signalling circuit
- Electrical durability 2 Mcycles 9 A AC-3 <= 440 V
- Provided equipment Protective cover
- Interlocking type Mechanical
- Mounting support Plate
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Standards CSA C22.2 No 14
- IEC 60947-5-1
- EN 60947-5-1
- EN 60947-4-1
- UL 508
- IEC 60947-4-1
- Product certifications GOST
- CCC
- LROS
- BV
- GL
- UL
- RINA
- DNV
- CSA
- Complementary
- Connections - terminals Screw clamp terminals for power circuit 1 1...4 mm² flexible without cable end
- Screw clamp terminals for power circuit 2 1...4 mm² flexible without cable end
- Screw clamp terminals for power circuit 1 1...4 mm² flexible with cable end
- Screw clamp terminals for power circuit 2 1...2.5 mm² flexible with cable end
- Screw clamp terminals for power circuit 1 1...4 mm² solid without cable end
- Screw clamp terminals for power circuit 2 1...4 mm² solid without cable end
- Screw clamp terminals for control circuit 1 1...4 mm² flexible without cable end
- Screw clamp terminals for control circuit 2 1...4 mm² flexible without cable end
- Screw clamp terminals for control circuit 1 1...4 mm² flexible with cable end
- Screw clamp terminals for control circuit 2 1...2.5 mm² flexible with cable end
- Screw clamp terminals for control circuit 1 1...4 mm² solid without cable end
- Screw clamp terminals for control circuit 2 1...4 mm² solid without cable end
- Tightening torque 1.7 N.m for power circuit screw clamp terminals flat Ø 6 mm
- 1.7 N.m for power circuit screw clamp terminals Philips No 2
- 1.7 N.m for control circuit screw clamp terminals flat Ø 6 mm
- 1.7 N.m for control circuit screw clamp terminals Philips No 2
- Mechanical durability 15 Mcycles
- Operating rate 30 cyc/h at <= 60 °C Starting time 30 s Coil technology Without built-in suppressor module Control circuit voltage limits 0.3...0.6 Uc at 60 °C drop-out 50/60 Hz 0.8...1.1 Uc at 60 °C operational 50 Hz 0.85...1.1 Uc at 60 °C operational 60 Hz Inrush power in VA 70 VA at 20 °C 0.75 60 Hz 70 VA at 20 °C 0.75 50 Hz Hold-in power consumption in VA 7.5 VA at 20 °C 0.3 60 Hz 7 VA at 20 °C 0.3 50 Hz Heat dissipation 2...3 W at 50/60 Hz Auxiliary contacts type Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact conforming to IEC 60947-4-1 3 x 1 NC Signalling circuit frequency 25...400 Hz Minimum switching current 5 mA for signalling circuit Switching voltage 17 V for signalling circuit Non-overlap time 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact Width 143 mm Height 124 mm Depth 143 mm Product weight 1.53 kg Environment Insulation resistance > 10 MOhm for signalling circuit
- IP degree of protection IP20 front face conforming to IEC 60529
- Protective treatment TH conforming to IEC 60068-2-30
- Pollution degree 3
- 2
- Ambient air temperature for storage -60...80 °C
- Ambient air temperature for operation -40...70 °C at Uc
- Operating altitude 3000 m without derating in temperature
- Fire resistance 850 °C conforming to IEC 60695-2-1
- Flame retardance V1 conforming to UL 94
- Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz
- Vibrations contactor closed 4 Gn, 5...300 Hz
- Shocks contactor open 10 Gn for 11 ms
- Shocks contactor closed 15 Gn for 11 ms
- Offer Sustainability
- Sustainable offer status Green Premium product
- RoHS (date code: YYWW) Compliant - since 0845 - Schneider Electric declaration of conformity
- Schneider Electric declaration of conformity
- REACh Reference not containing SVHC above the threshold
- Reference not containing SVHC above the threshold
- Product environmental profile Available
- Product environmental
- Product end of life instructions Available
- End of life manual
- Contractual warranty
- Warranty period 18 months
- 3
- Product data sheet
- LC3D09AE7
- Dimensions Drawings
- Dimensions
- LC3 D09A D12A D18A D32A
- a 143 143 144 165
- b 26.5 26.5 26.5 32.5
- c with LAD S 139 139 139 145
- with LAD S and sealing cover 143 143 143 149
- 4
- Product data sheet
- LC3D09AE7
- Connections and Schema
- Wiring
- (1) Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end).
- (2) Remote control.
- NOTE: LC3 D09A to D18A: Mechanical interlock between KM3 and KM1.
- 5
- Product data sheet
- LC3D09AE7
- Motor Starter BOM
- Our Proposal - Type 1 : Circuit Breaker + Contactor for Motor Power 7,5 kW and 415 VAC
- Motor Power Icu Breaker Contactor
- (kW) (kA)
- 7.5 15
- GV2ME20 LC3D09AE7
- Non contractual pictures. Type 1 coordination requires that in a short-circuit condition, the contactor or starter must not present any danger to
- personnel or installations and must not be able to resume operation without repair or the replacement of parts.
- 6
Produits Similaires
Produits similaires
Produits récemment consultés
Aucun produit récemment consulté à afficher