CONTACTOR BREAKER 63

258.086,84DZD

UGS : 76eddb54ce9e

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

LD1LD030U Marque : Schneider Disponibilité : En Stock



  • LD1LD030U
  • Characteristics
  • TeSys Integral - contactor breaker - 63 A AC-43 -
  • 240 V AC coil
  • Main
  • Range TeSys
  • Product name TeSys Integral 63
  • Product or component type Contactor breaker
  • Device short name LD1LD
  • Complementary
  • Utilisation category AC-43
  • Poles description 3P
  • [Ue] rated operational voltage 690 V AC 50/60 Hz
  • [Ie] rated operational current 63 A AC AC-43
  • [Ith] conventional free air thermal 63 A at <= 40 °C
  • current
  • Motor power kW 30 kW at 400 V AC 50/60 Hz
  • 33 kW at 415 V AC 50/60 Hz
  • 55 kW at 660 V AC 50/60 Hz
  • 15 kW at 220...240 V AC 50/60 Hz
  • 33 kW at 440 V AC 50/60 Hz
  • 37 kW at 500 V AC 50/60 Hz
  • Control circuit voltage 240 V AC 50 Hz
  • Control type Knob black front
  • Irms rated making capacity 756...946 A conforming to IEC 60947-4
  • [Ipk] rated peak withstand current 105 kA conforming to IEC 60947-2
  • Breaking capacity Icu 10 kA at 600...690 V (cos f 0.5) conforming to IEC 60947-2
  • Icu 30 kA at 480...525 V (cos f 0.25) conforming to IEC 60947-6-2
  • Icu 50 kA at <= 440 V (cos f 0.25) conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 10 kA at 600...690 V conforming to IEC 60947-2
  • 35 kA at 480...525 V conforming to IEC 60947-2
  • 50 kA at <= 440 V conforming to IEC 60947-2
  • Maximum breaking time 4 ms
  • Thermal stress limit 300000 A².s
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-4
  • Control circuit voltage limits 0.25...0.7 Uc drop-out at <= 55 °C
  • 0.85...1.1 Uc operation at <= 55 °C
  • [Ui] rated insulation voltage 690 V conforming to IEC 60947-1
  • Inrush power in VA 375 VA at 20 °C 50 Hz
  • Hold-in power consumption in VA 25 VA at 20 °C
  • Heat dissipation 5 W at 32 A per pole, hot state for power circuit
  • 7 W at 50 A per pole, hot state for power circuit
  • 8 W at 50 Hz for control circuit
  • 9 W at 63 A per pole, hot state for power circuit
  • 4.4 W at 25 A per pole, hot state for power circuit
  • 5.8 W at 40 A per pole, hot state for power circuit
  • Operating time 12...35 ms AC network closing at 20 °C for control circuit
  • 7...20 ms AC network opening at 20 °C for control circuit
  • Electrical durability 1 Mcycles on AC-3 - Icu 3 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
  • 0.9 Mcycles on AC-3 - Icu 10 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
  • 0.6 Mcycles on AC-3 - Icu 25 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
  • 0.5 Mcycles on AC-3 - Icu 35 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
  • 0.2 Mcycles on AC-3 - Icu 50 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
  • Mechanical durability 1.2 Mcycles
  • Connections - terminals Power circuit : screw clamp terminals 1 cable 6...50 mm² - cable stiffness: flexible - without cable end
  • Power circuit : screw clamp terminals 2 cable 6...25 mm² - cable stiffness: flexible - without cable end
  • Power circuit : screw clamp terminals 1 cable 6...25 mm² - cable stiffness: flexible - with cable end
  • Power circuit : screw clamp terminals 2 cable 6...25 mm² - cable stiffness: flexible - with cable end
  • Power circuit : screw clamp terminals 1 cable 6...50 mm² - cable stiffness: solid
  • Tightening torque Power circuit : 6 N.m - on screw clamp terminals
  • Width 90 mm
  • Height 243 mm
  • Depth 192 mm
  • Product weight 3.7 kg
  • Environment
  • Standards BS 4752
  • BS 4941
  • BS 5424
  • IEC 60158-1
  • IEC 60204-1
  • IEC 60204-2
  • IEC 60364
  • IEC 60947-1
  • IEC 60947-2
  • IEC 60947-4
  • NBN
  • NEN
  • NF C 20-040
  • NF C 63-110
  • NF C 63-120
  • NF C 63-130
  • NF C 63-650
  • NF C 79-100
  • VDE 0100
  • VDE 0110
  • VDE 0113
  • VDE 0170
  • VDE 0171
  • VDE 0660
  • VDE 471
  • Product certifications ASE
  • ASEFA
  • ASTA
  • BV
  • CSA
  • DEMKO
  • DNV
  • GL
  • LROS (Lloyds register of shipping)
  • NEMKO
  • 2
  • NKK
  • OVE
  • RINA
  • SCC
  • SETI
  • UL
  • USSR
  • Protective treatment TH
  • Ambient air temperature for operation -20...60 °C
  • Ambient air temperature for storage -40...80 °C
  • Mechanical robustness Vibrations de-energised state 3 Gn, 1...300 Hz
  • Vibrations energised state 3 Gn, 1...300 Hz
  • Shocks de-energised state 8 Gn for 11 ms
  • Shocks energised state 8 Gn for 11 ms
  • IP degree of protection IP20 B conforming to IEC 60144
  • IP20 B conforming to IEC 60529
  • Operating altitude 3000 m without derating
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

13
    13
    Votre panier
    XCKN2103P20
    XCKN2103P20
    1 X 2.702,40DZD = 2.702,40DZD
    XU1N18PP341W
    XU1N18PP341W
    1 X 23.326,30DZD = 23.326,30DZD
    A9D41640
    A9D41640
    1 X 6.812,47DZD = 6.812,47DZD
    ABE7H20E000
    ABE7H20E000
    1 X 8.196,49DZD = 8.196,49DZD
    K10D024MCH
    K10D024MCH
    2 X 6.763,32DZD = 13.526,64DZD
    XPEM929
    XPEM929
    2 X 40.383,96DZD = 80.767,92DZD
    PKF16M433
    PKF16M433
    1 X 1.412,67DZD = 1.412,67DZD
    LC1DTK12V7
    LC1DTK12V7
    1 X 39.754,62DZD = 39.754,62DZD
    MVS20N3NF6L
    MVS20N3NF6L
    1 X 586.306,44DZD = 586.306,44DZD