LD4LD030MC
CONTACTOR BREAKER 63
306.364,35DZD
UGS :
ea774db1d515
Spécificités essentielles
Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie :
Produits associés
- Quick ViewAjouter au panier
ZC4GM9
159.329,68DZD - Quick ViewAjouter au panier
ZC4GM8
149.050,35DZD - Quick ViewAjouter au panier
ZC4GM4
12.574,63DZD
Produits liés à cet article
Référence : LD4LD030MC
Marque : Schneider
Disponibilité : En Stock
- LD4LD030MC
- Characteristics
- TeSys Integral - contactor breaker - 63 A A AC-43
- - 230...240 V AC coil
- Main
- Range TeSys
- Product name TeSys Integral 63
- Product or component type Contactor breaker
- Device short name LD4LD
- Complementary
- Utilisation category AC-1
- AC-43
- Poles description 3P
- [Ue] rated operational voltage 690 V AC 50/60 Hz
- [Ie] rated operational current 63 A AC AC-1
- 63 A AC AC-43
- [Ith] conventional free air thermal 63 A at <= 40 °C
- current
- Motor power kW 30 kW at 400 V AC 50/60 Hz
- 33 kW at 415 V AC 50/60 Hz
- 55 kW at 660 V AC 50/60 Hz
- 15 kW at 220...240 V AC 50/60 Hz
- 33 kW at 440 V AC 50/60 Hz
- 37 kW at 500 V AC 50/60 Hz
- Control circuit voltage 230...240 V AC 60 Hz
- Test function Self test
- Control type Knob emergency stop red front conforming to CNOMO
- Irms rated making capacity 756...946 A conforming to IEC 60947-4
- [Ipk] rated peak withstand current 105 kA conforming to IEC 60947-2
- Breaking capacity Icu 10 kA at 600...690 V (cos f 0.5) conforming to IEC 60947-2
- Icu 30 kA at 480...525 V (cos f 0.25) conforming to IEC 60947-6-2
- Icu 50 kA at <= 440 V (cos f 0.25) conforming to IEC 60947-2
- [Ics] rated service breaking capacity 10 kA at 600...690 V conforming to IEC 60947-2
- 35 kA at 480...525 V conforming to IEC 60947-2
- 50 kA at <= 440 V conforming to IEC 60947-2
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Maximum breaking time 4 ms
- Thermal stress limit 300000 A².s
- [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-4
- Control circuit voltage limits 0.25...0.7 Uc drop-out at <= 55 °C
- 0.85...1.1 Uc operation at <= 55 °C
- [Ui] rated insulation voltage 690 V conforming to IEC 60947-1
- Inrush power in VA 450 VA at 20 °C 60 Hz
- Hold-in power consumption in VA 25 VA at 20 °C
- Heat dissipation 11 W at 60 Hz for control circuit
- 5 W at 32 A per pole, hot state for power circuit
- 7 W at 50 A per pole, hot state for power circuit
- 9 W at 63 A per pole, hot state for power circuit
- 4.4 W at 25 A per pole, hot state for power circuit
- 5.8 W at 40 A per pole, hot state for power circuit
- Operating time 12...35 ms AC network closing at 20 °C for control circuit
- 7...20 ms AC network opening at 20 °C for control circuit
- Electrical durability 1 Mcycles on AC-3 - Icu 3 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
- 0.9 Mcycles on AC-3 - Icu 10 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
- 0.6 Mcycles on AC-3 - Icu 25 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
- 0.5 Mcycles on AC-3 - Icu 35 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
- 0.2 Mcycles on AC-3 - Icu 50 kA - at 415 V - after 1 cycle O-CO-r-CO at Isc
- Mechanical durability 1.2 Mcycles
- Connections - terminals Power circuit : screw clamp terminals 1 cable 6...50 mm² - cable stiffness: flexible - without cable end
- Power circuit : screw clamp terminals 2 cable 6...25 mm² - cable stiffness: flexible - without cable end
- Power circuit : screw clamp terminals 1 cable 6...25 mm² - cable stiffness: flexible - with cable end
- Power circuit : screw clamp terminals 2 cable 6...25 mm² - cable stiffness: flexible - with cable end
- Power circuit : screw clamp terminals 1 cable 6...50 mm² - cable stiffness: solid
- Tightening torque Power circuit : 6 N.m - on screw clamp terminals
- Width 90 mm
- Height 243 mm
- Depth 192 mm
- Product weight 3.8 kg
- Environment
- Standards BS 4752
- BS 4941
- BS 5424
- IEC 60158-1
- IEC 60204-1
- IEC 60204-2
- IEC 60364
- IEC 60947-1
- IEC 60947-2
- IEC 60947-4
- NBN
- NEN
- NF C 20-040
- NF C 63-110
- NF C 63-120
- NF C 63-130
- NF C 63-650
- NF C 79-100
- VDE 0100
- VDE 0110
- VDE 0113
- VDE 0170
- VDE 0171
- VDE 0660
- VDE 471
- Product certifications ASE
- ASEFA
- ASTA
- BV
- CSA
- DEMKO
- DNV
- GL
- 2
- LROS (Lloyds register of shipping)
- NEMKO
- NKK
- OVE
- RINA
- SCC
- SETI
- UL
- USSR
- Protective treatment TH
- Ambient air temperature for operation -20...60 °C
- Ambient air temperature for storage -40...80 °C
- Mechanical robustness Vibrations de-energised state 3 Gn, 1...300 Hz
- Vibrations energised state 3 Gn, 1...300 Hz
- Shocks de-energised state 8 Gn for 11 ms
- Shocks energised state 8 Gn for 11 ms
- IP degree of protection IP20 B conforming to IEC 60144
- IP20 B conforming to IEC 60529
- Operating altitude 3000 m without derating
- Contractual warranty
- Warranty period 18 months
- 3