LV431155

4P4T MICROLOGIC 5.2 A 250A NSX250B

178.124,15DZD

UGS : e93e48498dfd

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

LV431155 Marque : Schneider Disponibilité : En Stock



  • LV431155
  • Characteristics
  • circuit breaker Compact NSX250B - Micrologic
  • 5.2 A - 250 A - 4 poles 4d
  • Main
  • Range Compact
  • Product name Compact NSX
  • Product or component type Circuit breaker
  • Device short name Compact NSX250B
  • Device application Distribution
  • Poles description 4P
  • Protected poles description 3t
  • 3t + 1.6 N
  • 3t + N/2
  • 4t
  • Neutral position Left
  • Network type AC
  • Network frequency 50/60 Hz
  • [In] rated current 250 A ( 40 °C )
  • [Ui] rated insulation voltage 800 V AC 50/60 Hz
  • [Uimp] rated impulse withstand voltage 8 kV
  • [Ue] rated operational voltage 690 V AC 50/60 Hz
  • Breaking capacity code B
  • Breaking capacity 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  • 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  • 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  • 20 kA at 480 V AC 50/60 Hz conforming to NEMA AB1
  • 40 kA at 240 V AC 50/60 Hz conforming to NEMA AB1
  • [Ics] rated service breaking capacity Ics 15 kA 500 V AC 50/60 Hz conforming to IEC 60947-2
  • Ics 20 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
  • Ics 25 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  • Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Utilisation category Category A
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Trip unit name Micrologic 5.2 A
  • Trip unit technology Electronic
  • Trip unit protection functions LSI
  • Trip unit rating 250 A ( 40 °C )
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Pollution degree 3 conforming to IEC 60664-1
  • Complementary
  • Control type Toggle
  • Mounting mode Fixed
  • Mounting support Backplate
  • Upside connection Front
  • Downside connection Front
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles 440 V In conforming to IEC 60947-2
  • 10000 cycles 690 V In/2 conforming to IEC 60947-2
  • 20000 cycles 440 V In/2 conforming to IEC 60947-2
  • 5000 cycles 690 V In conforming to IEC 60947-2
  • Connection pitch 35 mm
  • Local signalling LED 105 % Ir
  • LED 90 % Ir
  • LED ready
  • Neutral protection setting 0.5 x Ir 3t + N/2
  • 1 x Ir 4t
  • 1.6 x Ir 3t + OSN
  • No protection 3t
  • Long time pick-up adjstment type Ir Adjustable
  • Long time pick-up adjustment range 100...250 A
  • Long time delay adjustment type Adjustable
  • [Tr] long-time delay adjustment 15...400 s 1.5 x Ir
  • 0.35...11 s 7.2 x Ir
  • 0.5...16 s 6 x Ir
  • Thermal memory 20 minutes before and after tripping
  • Short-time pick-up adjustment type Isd Adjustable
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable
  • [Tsd] short-time delay adjustment 0...0.4 s
  • range
  • Instantaneous pick-up adjustment type Adjustable
  • Ii
  • Instantaneous pick-up adjustment 1.5...12 x In
  • range
  • Zone selective interlocking ZSI With
  • Communication of data Demand current and power
  • Energy metering
  • Instantaneous and demand values
  • Maintenance indicators
  • Maximeters/Minimeters
  • Power quality
  • Protection and alarm settings
  • Time-stamped histories and event tables
  • Display type LCD display
  • Type of measurement Ammeter
  • Electrical data recording Maintenance indicators
  • Height 161 mm
  • Width 140 mm
  • 2
  • Depth 86 mm
  • Product weight 2.8 kg
  • Environment
  • Electrical shock protection class Class II
  • Standards EN 60947-2
  • IEC 60947-2
  • NEMA AB1
  • UL 508
  • Product certifications CSA
  • UL
  • IP degree of protection IP40 conforming to IEC 60529
  • IK degree of protection IK07 conforming to IEC 62262
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -55...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  0819  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    4512360
    4512360
    1 X 0,00DZD = 0,00DZD
    XPEM810
    XPEM810
    1 X 15.222,33DZD = 15.222,33DZD
    XC010L2
    XC010L2
    1 X 5.064,07DZD = 5.064,07DZD
    PRA15418
    PRA15418
    1 X 8.331,02DZD = 8.331,02DZD
    AB1GF
    AB1GF
    1 X 56,35DZD = 56,35DZD
    FR22GG69V50P
    FR22GG69V50P
    1 X 0,00DZD = 0,00DZD
    ABT7PDU016B
    ABT7PDU016B
    1 X 9.602,48DZD = 9.602,48DZD
    ATV630U30M3
    ATV630U30M3
    1 X 180.615,36DZD = 180.615,36DZD
    1344850000
    1344850000
    1 X 54.474,00DZD = 54.474,00DZD