- Characteristics
- Easypact CVS - CVS100F Vigi MH TM50D circuit
- breaker - 4P/3d
- Main
- Range of product Easypact CVS100...250
- Product or component type Earth leakage circuit breaker
- Device short name Vigi CVS100F
- Device application Distribution
- Poles description 4P
- Protected poles description 3d
- Neutral position Left
- Earth-leakage protection With
- [In] rated current 100 A ( 40 °C )
- Breaking capacity code F
- Network type AC
- [Ue] rated operational voltage 440 V AC conforming to EN/IEC 60947-2 50/60 Hz
- Breaking capacity 36 kA Icu conforming to IEC 60947-2 at 440 V AC 50/60 Hz
- 36 kA Icu conforming to IEC 60947-2 at 380/415 V AC 50/60 Hz
- 70 kA Icu conforming to IEC 60947-2 at 220/240 V AC 50/60 Hz
- Utilisation category Category A
- Trip unit name TM-D
- Trip unit technology Thermal-magnetic
- Trip unit rating 50 A ( 40 °C )
- Protection type Overload protection (thermal)
- Short-circuit protection (magnetic)
- Earth-leakage add-on module name MH
- Complementary
- Network frequency 50/60 Hz
- Control type Toggle
- Mounting mode Fixed
- Mounting support Backplate
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Upside connection Front
- Downside connection Front
- [Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-2
- [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
- [Ics] rated service breaking capacity 18 kA conforming to IEC 60947-2 440 V AC 50/60 Hz
- 36 kA conforming to IEC 60947-2 380/415 V AC 50/60 Hz
- 70 kA conforming to IEC 60947-2 220/240 V AC 50/60 Hz
- Mechanical durability 30000 cycles
- Electrical durability 12000 cycles conforming to IEC 60947-2 415 V In
- Connection pitch 35 mm
- Contact position indicator Yes
- Neutral protection setting No protection 3d
- Long time pick-up adjstment type Ir Adjustable
- Long time pick-up adjustment range 0.7...1 x In
- Long time delay adjustment type Fixed
- Short-time delay adjustment type Fixed
- Instantaneous pick-up adjustment type Fixed
- Ii
- Instantaneous pick-up adjustment 500 A
- range
- Earth-leakage protection class Class A
- Residual earth-leakage sensitity Adjustable 5 settings
- adjustment type
- [Δt] residual earth-leakage sensitive 0.03 A
- adjustment 0.3 A
- 1 A
- 10 A
- 3 A
- Residual earth-leakage time delay Adjustable 5 settings
- adjustment type
- [Δt] residual earth-leakage time delay 0 ms < 40 ms
- adjustment 150 ms < 300 ms
- 310 ms < 800 ms
- 60 ms < 140 ms
- Height 236 mm
- Width 140 mm
- Depth 86 mm
- Environment
- Electrical shock protection class Class II
- Standards EN 60947-2
- IEC 60947-2
- Product certifications GOST
- IEC
- Pollution degree 3 conforming to IEC 60947-1
- Ambient air temperature for operation -25...70 °C
- Ambient air temperature for storage -50...85 °C
- Contractual warranty
- Warranty period 18 months