Référence :

LV525402 Marque : Schneider Disponibilité : En Stock



  • LV525402
  • Characteristics
  • Easypact CVS - CVS250F Vigi MH TM200D
  • circuit breaker - 4P/3d
  • Main
  • Range of product Easypact CVS100...250
  • Product or component type Earth leakage circuit breaker
  • Device short name Vigi CVS250F
  • Device application Distribution
  • Poles description 4P
  • Protected poles description 3d
  • Neutral position Left
  • Earth-leakage protection With
  • [In] rated current 250 A ( 40 °C )
  • Breaking capacity code F
  • Network type AC
  • [Ue] rated operational voltage 440 V AC conforming to EN/IEC 60947-2 50/60 Hz
  • Breaking capacity 36 kA Icu conforming to IEC 60947-2 at 440 V AC 50/60 Hz
  • 36 kA Icu conforming to IEC 60947-2 at 380/415 V AC 50/60 Hz
  • 70 kA Icu conforming to IEC 60947-2 at 220/240 V AC 50/60 Hz
  • Utilisation category Category A
  • Trip unit name TM-D
  • Trip unit technology Thermal-magnetic
  • Trip unit rating 200 A ( 40 °C )
  • Protection type Overload protection (thermal)
  • Short-circuit protection (magnetic)
  • Earth-leakage add-on module name MH
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Toggle
  • Mounting mode Fixed
  • Mounting support Backplate
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Upside connection Front
  • Downside connection Front
  • [Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-2
  • [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
  • [Ics] rated service breaking capacity 18 kA conforming to IEC 60947-2 440 V AC 50/60 Hz
  • 36 kA conforming to IEC 60947-2 380/415 V AC 50/60 Hz
  • 70 kA conforming to IEC 60947-2 220/240 V AC 50/60 Hz
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles conforming to IEC 60947-2 415 V In
  • Connection pitch 35 mm
  • Contact position indicator Yes
  • Neutral protection setting No protection 3d
  • Long time pick-up adjstment type Ir Adjustable
  • Long time pick-up adjustment range 0.7...1 x In
  • Long time delay adjustment type Fixed
  • Short-time delay adjustment type Fixed
  • Instantaneous pick-up adjustment type Fixed
  • Ii
  • Instantaneous pick-up adjustment 2000 A
  • range
  • Earth-leakage protection class Class A
  • Residual earth-leakage sensitity Adjustable 5 settings
  • adjustment type
  • [Δt] residual earth-leakage sensitive 0.03 A
  • adjustment 0.3 A
  • 1 A
  • 10 A
  • 3 A
  • Residual earth-leakage time delay Adjustable 5 settings
  • adjustment type
  • [Δt] residual earth-leakage time delay 0 ms < 40 ms
  • adjustment 150 ms < 300 ms
  • 310 ms < 800 ms
  • 60 ms < 140 ms
  • Height 236 mm
  • Width 140 mm
  • Depth 86 mm
  • Environment
  • Electrical shock protection class Class II
  • Standards EN 60947-2
  • IEC 60947-2
  • Product certifications GOST
  • IEC
  • Pollution degree 3 conforming to IEC 60947-1
  • Ambient air temperature for operation -25...70 °C
  • Ambient air temperature for storage -50...85 °C
  • Contractual warranty
  • Warranty period 18 months
  • 2

20 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

Panier