LV540309
UGS : af7cf4610335
Catégorie : Disjoncteurs forte puissance (boitier moulé et ouvert)
CVS400F TM400D 4P3D
112.555,50DZD
UGS :
af7cf4610335
Spécificités essentielles
Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie :
Produits associés
- Quick ViewAjouter au panier
TRV00917
58.540,65DZD - Quick ViewAjouter au panier
TRV00880
5.930,02DZD - Quick ViewAjouter au panier
TRV00870
9.386,85DZD
Produits liés à cet article
Référence : LV540309
Marque : Schneider
Disponibilité : En Stock
- LV540309
- Characteristics
- Easypact CVS - CVS400F TM400D circuit
- breaker - 4P/3d
- Main
- Range of product Easypact CVS400...630
- Product or component type Circuit breaker
- Device short name CVS400F
- Device application Distribution
- Poles description 4P
- Protected poles description 3d
- Neutral position Left
- Earth-leakage protection Without
- [In] rated current 400 A ( 40 °C )
- Breaking capacity code F
- Network type AC
- [Ue] rated operational voltage 440 V AC conforming to EN/IEC 60947-2 50/60 Hz
- Breaking capacity 36 kA Icu conforming to IEC 60947-2 at 380/415 V AC 50/60 Hz
- 30 kA Icu conforming to IEC 60947-2 at 440 V AC 50/60 Hz
- 40 kA Icu conforming to IEC 60947-2 at 220/240 V AC 50/60 Hz
- Utilisation category Category A
- Local signalling LED 90 % Ir
- LED 105 % Ir
- LED ready
- Trip unit name TM-D
- Trip unit technology Thermal-magnetic
- Trip unit rating 400 A ( 40 °C )
- Protection type Overload protection (thermal)
- Short-circuit protection (magnetic)
- Complementary
- Network frequency 50/60 Hz
- Control type Toggle
- Mounting mode Fixed
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Mounting support Backplate
- Upside connection Front
- Downside connection Front
- Connections - terminals Screw connection
- [Ui] rated insulation voltage 690 V conforming to EN/IEC 60947-2
- [Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
- Thermal protection adjustment range 0...400 A
- [Ics] rated service breaking capacity 40 kA conforming to IEC 60947-2 220/240 V AC 50/60 Hz
- 36 kA conforming to IEC 60947-2 380/415 V AC 50/60 Hz
- 23 kA conforming to IEC 60947-2 440 V AC 50/60 Hz
- Mechanical durability 15000 cycles
- Electrical durability 6000 cycles conforming to IEC 60947-2 415 V In
- Connection pitch 45 mm
- Contact position indicator Yes
- Neutral protection setting No protection 3d
- Long time pick-up adjstment type Ir Adjustable
- Long time pick-up adjustment range 0.7...1 x In
- Long time delay adjustment type Fixed
- Short-time delay adjustment type Fixed
- Instantaneous pick-up adjustment type Adjustable
- Ii
- Instantaneous pick-up adjustment 5...10 x In
- range
- Height 255 mm
- Width 185 mm
- Depth 110 mm
- Environment
- Electrical shock protection class Class II
- Standards IEC 60947-2
- EN 60947-2
- Product certifications GOST
- IEC
- IP degree of protection IP40
- Pollution degree 3 conforming to IEC 60947-1
- Ambient air temperature for operation -25...70 °C
- Ambient air temperature for storage -50...85 °C
- Offer Sustainability
- Sustainable offer status Not Green Premium product
- RoHS (date code: YYWW) Compliant - since 1041 - Schneider Electric declaration of conformity
- Schneider Electric declaration of conformity
- REACh Reference not containing SVHC above the threshold
- Reference not containing SVHC above the threshold
- Product environmental profile Available
- End of life manual
- Contractual warranty
- Warranty period 18 months
- 2
Produits Similaires
Produits similaires
Produits récemment consultés
Aucun produit récemment consulté à afficher