Nos marques

Tous les produits Schneider

Produits récemment consultés

08198

31.258,44DZD

LA1LC031

8.259,23DZD

08184

13.480,99DZD

OVA53004E

25.303,01DZD

MVS08H3MF2L

UGS : e53dd2a34ab3 Catégorie :
EP MVS CB 800A 65KA 3P MF ET2 FIXED MANU

515.596,11DZD

UGS : e53dd2a34ab3

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS08H3MF2L Marque : Schneider Disponibilité : En Stock



  • MVS08H3MF2L
  • Characteristics
  • EP MVS CB 800A 65kA 3P MF ET2 fixed manual
  • circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS08H
  • Device short name MVS08H
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code H
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET2I
  • Trip unit technology Electronic
  • Trip unit rating 800 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Fixed
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 800 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 800 A
  • Breaking capacity 65 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Thermal memory 20 minutes before and after tripping
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 1.5...10 x Ir
  • range
  • Zone selective interlocking ZSI With
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 352 mm
  • Width 422 mm
  • Depth 297 mm
  • Product weight 40 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Not Green Premium product
  • RoHS (date code: YYWW) Will be compliant  on  2Q2016
  • Will be compliant  on  2Q2016
  • REACh Reference not containing SVHC above the threshold
  • 2
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

12
    12
    Votre panier
    04946
    04946
    1 X 22.778,91DZD = 22.778,91DZD
    ETK16320
    ETK16320
    1 X 52,74DZD = 52,74DZD
    GB2CD06
    GB2CD06
    1 X 6.642,51DZD = 6.642,51DZD
    ALB44336N
    ALB44336N
    1 X 2.704,62DZD = 2.704,62DZD
    VZ1L250U100T
    VZ1L250U100T
    1 X 154.797,84DZD = 154.797,84DZD
    04773
    04773
    1 X 646,33DZD = 646,33DZD
    schneider
    14975
    1 X 550,29DZD = 550,29DZD
    81494
    81494
    1 X 17.331,53DZD = 17.331,53DZD
    NSYTJ2015
    NSYTJ2015
    1 X 5.733,80DZD = 5.733,80DZD
    AB1GY
    AB1GY
    1 X 54,10DZD = 54,10DZD
    XE2SP2141
    XE2SP2141
    1 X 2.629,83DZD = 2.629,83DZD
    MVS08N3MW5V
    MVS08N3MW5V
    1 X 703.420,41DZD = 703.420,41DZD