Nos marques

Tous les produits Schneider

Produits récemment consultés

ATS22D17Q

82.816,64DZD

08064

47.078,61DZD

LA1LC030

2.426,15DZD

A9F85116

2.386,46DZD

MVS08H3MF6L

UGS : c88487c86b87 Catégorie :
EP MVS CB 800A 65KA 3P MF ET6 FIXED MANU

540.148,31DZD

UGS : c88487c86b87

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS08H3MF6L Marque : Schneider Disponibilité : En Stock



  • MVS08H3MF6L
  • Characteristics
  • EP MVS CB 800A 65kA 3P MF ET6 fixed manual
  • circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS08H
  • Device short name MVS08H
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code H
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET6G
  • Trip unit technology Electronic
  • Trip unit rating 800 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Fixed
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 800 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 800 A
  • Breaking capacity 65 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LSIG
  • Protection type Earth fault
  • Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Earth fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Ground-fault pick-up adjustment type Adjustable 9 settings
  • Ground-fault time delay adjustment Adjustable 5 settings
  • type -tg
  • [Tg] ground-fault time delay 100...400 ms
  • adjustment range
  • [Ig] ground-fault pick-up adjustment 0.2...1 x In
  • range
  • Zone selective interlocking ZSI With
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 352 mm
  • Width 422 mm
  • Depth 297 mm
  • Product weight 40 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • 2
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    140ACI04000
    140ACI04000
    1 X 263.693,15DZD = 263.693,15DZD
    schneider
    CA2KN22FE72
    1 X 4.406,32DZD = 4.406,32DZD
    schneider
    ZC4GM8
    1 X 149.050,35DZD = 149.050,35DZD
    KBA40ABD4W
    KBA40ABD4W
    1 X 8.159,40DZD = 8.159,40DZD
    C22-P
    C22-P
    1 X 0,00DZD = 0,00DZD
    ATS01N125FT
    ATS01N125FT
    1 X 29.631,74DZD = 29.631,74DZD
    ZCMD39L5
    ZCMD39L5
    1 X 9.887,19DZD = 9.887,19DZD
    CA2KN22N7
    CA2KN22N7
    1 X 4.085,86DZD = 4.085,86DZD
    A9S70790
    A9S70790
    1 X 6.814,18DZD = 6.814,18DZD
    MVS08N3MW5V
    MVS08N3MW5V
    1 X 703.420,41DZD = 703.420,41DZD