Nos marques

Tous les produits Schneider

Produits récemment consultés

82363

2.782,19DZD

04921

15.304,18DZD

AB1GR

56,14DZD

MVS08N3NF2L

574.521,38DZD

MVS08H3NW5L

UGS : 71562aecfe73 Catégorie :
EP MVS CB 800A 65KA 3P EDO 240VAC ET5 DR

853.323,06DZD

UGS : 71562aecfe73

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS08H3NW5L Marque : Schneider Disponibilité : En Stock



  • MVS08H3NW5L
  • Characteristics
  • EP MVS CB 800A 65kA 3P EDO 240VAC ET5
  • drawout electrical circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS08H
  • Device short name MVS08H
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code H
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET5S
  • Trip unit technology Electronic
  • Trip unit rating 800 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Electrically operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 800 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 800 A
  • Breaking capacity 65 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 36 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LSI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Zone selective interlocking ZSI With
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 441 mm
  • Depth 395 mm
  • Product weight 70 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Available
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

14
    14
    Votre panier
    08174
    08174
    1 X 28.422,74DZD = 28.422,74DZD
    KBA25ED4302W
    KBA25ED4302W
    1 X 7.474,53DZD = 7.474,53DZD
    schneider
    ZL1AB106
    1 X 6.055,99DZD = 6.055,99DZD
    A9S70740
    A9S70740
    1 X 6.805,91DZD = 6.805,91DZD
    10207
    10207
    1 X 1.019,85DZD = 1.019,85DZD
    VLVW011
    VLVW011
    1 X 50.694,22DZD = 50.694,22DZD
    16008
    16008
    1 X 515,14DZD = 515,14DZD
    MVS08N3MF6L
    MVS08N3MF6L
    1 X 508.230,46DZD = 508.230,46DZD
    XAPM3203
    XAPM3203
    1 X 7.520,10DZD = 7.520,10DZD
    KBA40ED4303W
    KBA40ED4303W
    1 X 16.413,74DZD = 16.413,74DZD
    10387
    10387
    1 X 723,62DZD = 723,62DZD
    KBA25ED4303W
    KBA25ED4303W
    1 X 13.503,32DZD = 13.503,32DZD
    10200
    10200
    2 X 1.192,23DZD = 2.384,46DZD