Nos marques

Tous les produits Schneider

Produits récemment consultés

AB1R6

51,65DZD

MVS25N4MW5A

1.143.940,05DZD

LX4D6GD

8.309,38DZD

ATV950C20N4F

5.345.702,73DZD

MVS08N3MW2A

UGS : 0e7b4494872a Catégorie :
EP MVS CB 800A 50KA 3P MDO ETA2 DRAWOUT

685.630,35DZD

UGS : 0e7b4494872a

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS08N3MW2A Marque : Schneider Disponibilité : En Stock



  • MVS08N3MW2A
  • Characteristics
  • EP MVS CB 800A 50kA 3P MDO ETA2 drawout
  • manual Circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS08N
  • Device short name MVS08N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ETA2I
  • Trip unit technology Electronic
  • Trip unit rating 800 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 800 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 800 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Thermal memory 20 minutes before and after tripping
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 1.5...10 x Ir
  • range
  • Zone selective interlocking ZSI With
  • Display type Digital display
  • Type of measurement Current
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 441 mm
  • Depth 395 mm
  • Product weight 70 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • 2
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    XUB0AKSNM12T
    XUB0AKSNM12T
    1 X 7.983,50DZD = 7.983,50DZD
    140CPS22400
    140CPS22400
    1 X 143.613,46DZD = 143.613,46DZD
    schneider
    ZC4GM8
    1 X 149.050,35DZD = 149.050,35DZD
    MVS08N3MW6L
    MVS08N3MW6L
    1 X 675.466,36DZD = 675.466,36DZD
    KSB1000ZV2
    KSB1000ZV2
    1 X 6.028,55DZD = 6.028,55DZD
    MVS08H3NW5L
    MVS08H3NW5L
    1 X 853.323,06DZD = 853.323,06DZD
    LC1D40AP7
    LC1D40AP7
    1 X 12.285,08DZD = 12.285,08DZD
    MGU6.008.873
    MGU6.008.873
    1 X 1.674,50DZD = 1.674,50DZD
    XCKN2121P20
    XCKN2121P20
    1 X 3.088,13DZD = 3.088,13DZD
    MVS08N3MW5L
    MVS08N3MW5L
    1 X 662.221,92DZD = 662.221,92DZD